Basit öğe kaydını göster

dc.contributor.authorÇalışır, Mehmet Durmuş
dc.date.accessioned2025-02-25T06:52:41Z
dc.date.available2025-02-25T06:52:41Z
dc.date.issued2025en_US
dc.identifier.citationCalisir, M. D. (2025). Performance Comparison of PVDF‐Based Unimodal and Bimodal Electret Air Filters via Solution‐Blowing and Electro‐Blowing Methods. Journal of Applied Polymer Science. https://doi.org/10.1002/app.56855en_US
dc.identifier.issn0021-8995
dc.identifier.issn1097-4628
dc.identifier.urihttps://doi.org/10.1002/app.56855
dc.identifier.urihttps://hdl.handle.net/11436/10057
dc.description.abstractIn this study, unimodal and bimodal PVDF nano/micro-fibrous filter mats are produced using electro-blowing (EB) and solution-blowing (SB) techniques. Fiber diameters are controlled by adjusting solution concentrations (10 and 20 wt%) and applying an electric field. Nanofibers from low-concentration solutions using EB averaged 236 nm, while fibers from high-concentration solutions via SB reached around 1 mu m. Both methods result in fiber bundles, with EB forming finer bundles and SB producing thicker ones. Defects such as droplets and beads are observed in SB, decreasing with the electric field and lower solution concentration. Bimodal mats show fiber distributions centered around 250 nm and 1 mu m. FTIR analysis reveals similar crystallization, with all samples dominated by the beta-phase and finer nanofibers increasing peak intensities. Filtration tests for PM0.3 at 15.83 cm/s show Sample A (EB) achieves the highest efficiency (95.95%) but also the highest resistance (250.33 Pa). Among bimodal samples, four-layered ABAB mats show the best quality factor (QF) with 84.67% efficiency and 145.25 Pa pressure drop, while Sample A + B achieves 88.24% efficiency with a lower pressure drop (169.50 Pa). Corona discharge treatment enhances filtration efficiency, with the sample ABAB reaching 94.55% efficiency and a 151.83 Pa pressure drop after treatment.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAir filtersen_US
dc.subjectBimodalen_US
dc.subjectElectro-blowingen_US
dc.subjectPVDFen_US
dc.subjectSolution blowingen_US
dc.titlePerformance comparison of PVDF-based unimodal and bimodal electret air filters via solution-blowing and electro-blowing methodsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Elektrik-Elektronik Mühendisliği Bölümüen_US
dc.contributor.institutionauthorÇalışır, Mehmet Durmuş
dc.identifier.doi10.1002/app.56855en_US
dc.relation.journalJournal of Applied Polymer Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster