dc.identifier.citationDemir, E., & Dursun, E. (2019). Utilization of incus with bone cement for total ossicular reconstruction. Acta oto-laryngologica, 139(11), 1044–1048. https://doi.org/10.1080/00016489.2019.1655168en_US
dc.identifier.issn0001-6489
dc.identifier.issn1651-2251
dc.identifier.urihttps://doi.org/10.1080/00016489.2019.1655168
dc.identifier.urihttps://hdl.handle.net/11436/1447
dc.descriptionWOS: 000483826300001en_US
dc.descriptionPubMed: 31453738en_US
dc.description.abstractBackground: Total ossicular chain reconstructions are performed to connect mobile stapes footplate and tympanic membrane. Data on the use of incus for total ossicular reconstruction is quite limited in the literature. Objective: the main objective of this study is to describe a novel surgical method that utilizes incus with bone cement to stabilize the ossicular chain for total ossicular reconstruction. Materials and methods: 16 patients who underwent total ossicular reconstruction using our method were included in this study. We evaluated hearing by comparing preoperative and postoperative air-bone gap (ABG), air conduction (AC) and bone conduction (BC). the percentage of patients achieving ABG <= 20 dB was determined. Results: the mean preoperative ABG was 35.3 +/- 8.2 and postoperative ABG decreased significantly to 23.7 +/- 7.6 (p < .001). the mean preoperative AC (57.5 +/- 10) decreased significantly postoperatively to (46.5 +/- 13.3)(p = .014). There was not any difference between pre- and post-operative BC. We achieved successful hearing results (ABG <= 20dB) in 44% of patients. Conclusion: the use of incus with bone cement stabilization for total ossicular reconstruction seems a feasible option. Good hearing outcomes, and low cost, complication, and extrusion rate may be the main reasons to prefer this method.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectOssiculoplastyen_US
dc.subjectTotal ossicular reconstructionen_US
dc.subjectIncusen_US
dc.subjectBone cementen_US
dc.titleUtilization of incus with bone cement for total ossicular reconstructionen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorDemir, Emine
dc.contributor.institutionauthorDursun, Engin
dc.identifier.doi10.1080/00016489.2019.1655168
dc.identifier.volume139en_US
dc.identifier.issue11en_US
dc.identifier.startpage1044en_US
dc.identifier.endpage1048en_US
dc.relation.journalActa Oto-Laryngologicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster