dc.contributor.author | Çevik, Uğur | |
dc.contributor.author | Kaya, Selim | |
dc.contributor.author | Ertuğral, Birol | |
dc.contributor.author | Baltaş, Hasan | |
dc.contributor.author | Karabidak, S.M. | |
dc.date.accessioned | 2020-12-19T20:13:03Z | |
dc.date.available | 2020-12-19T20:13:03Z | |
dc.date.issued | 2007 | |
dc.identifier.citation | Çevik, U., Kaya, S., Ertuğrul, B., Baltaş, H. & Karabidak, S.M. (2007). K-shell X-ray fluorescence cross-sections and intensity ratios for some pure metals at 59.5 and 123.6 keV. Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 262(2), 165-170. https://doi.org/10.1016/j.nimb.2007.06.007 | en_US |
dc.identifier.issn | 0168-583X | |
dc.identifier.uri | https://doi.org/10.1016/j.nimb.2007.06.007 | |
dc.identifier.uri | https://hdl.handle.net/11436/3969 | |
dc.description.abstract | K-shell X-ray fluorescence cross-sections for some pure metals such as Cr, Fe, Co, Cu, Zn, Ga, Se, Y, Mo, Cd, In, Sn, Te, Ba, Ta, W and Bi have been theoretically and experimentally determined. The Cr, Fe, Co, Cu, Zn, Ga, Se, Y, Mo, Cd, In, Sn, Te and Ba metals were excited by 59.5 keV ?-ray from 50 mCi 241Am radioactive source and the Ta, W and Bi targets were excited by 123.6 keV ?-ray from 25 mCi 57Co radioactive source. The characteristic K X-rays emitted by samples were detected by using a super Si(Li) detector having a resolution of 150 eV at 5.9 keV. In addition, the IK?/IK? intensity ratios for these metals were studied. The obtained experimental values of the K-shell X-ray fluorescence cross-sections and the IK?/IK? intensity ratios have been compared with theoretical values. The measured values were in good agreement with theoretical values. © 2007 Elsevier B.V. All rights reserved. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cross-sections | en_US |
dc.subject | EDXRF | en_US |
dc.subject | Intensity ratios | en_US |
dc.subject | Super Si(Li) detector | en_US |
dc.title | K-shell X-ray fluorescence cross-sections and intensity ratios for some pure metals at 59.5 and 123.6 keV | en_US |
dc.type | article | en_US |
dc.contributor.department | RTEÜ, Fen - Edebiyat Fakültesi, Fizik Bölümü | en_US |
dc.contributor.institutionauthor | Baltaş, Hasan | |
dc.identifier.doi | 10.1016/j.nimb.2007.06.007 | |
dc.identifier.volume | 262 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 165 | en_US |
dc.identifier.endpage | 170 | en_US |
dc.relation.journal | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |