Basit öğe kaydını göster

dc.contributor.authorJaffar, Abubakkar Abdul
dc.contributor.authorPandiaraj, Selvakumar
dc.contributor.authorGovindasamy, Kumaresan
dc.contributor.authorSharma, Kamal
dc.contributor.authorMuthusamy, Suresh
dc.contributor.authorSiddiqui, Mohammad Irfanul Haque
dc.contributor.authorCüce, Erdem
dc.contributor.authorShah, Mohd Asif
dc.date.accessioned2024-08-19T12:15:52Z
dc.date.available2024-08-19T12:15:52Z
dc.date.issued2024en_US
dc.identifier.citationJaffar, A. A., Pandiaraj, S., Govindasamy, K., Sharma, K., Muthusamy, S., Siddiqui, M. I. H., Cuce, E., & Shah, M. A. (2024). Thermal comfort inside a gable-roofed metallic shed in a higher educational institution: a case study and detailed analysis. International Journal of Low-Carbon Technologies, 19, 1660–1673. https://doi.org/10.1093/ijlct/ctae115en_US
dc.identifier.issn1748-1317
dc.identifier.issn1748-1325
dc.identifier.urihttps://doi.org/10.1093/ijlct/ctae115
dc.identifier.urihttps://hdl.handle.net/11436/9281
dc.description.abstractCentral workshop is an integral part of any higher education institution, and it will be generally operated in a gable-roofed metallic shed. The users of the building are affected physiologically and psychologically due to the thermal discomfort conditions caused by improper ventilation. It is necessary to study the cause for discomfort and propose cost and effective methods to mitigate the problem. In this work, the thermal comfort inside a gable-roofed workshop was analyzed, and it was found that the discomfort was predominant from 2 PM to 5 PM. It was predicted that the conduction heat transfer could be reduced upto 55% with the help of passive cooling technique carried out using aluminium bubble wrap. During the life cycle cost study, the aluminium bubble wrap technique was found to be more economical over high-volume low-speed fan. The computer simulation aided in the prediction of overall heat transfer coefficient and conduction heat transfer through wall. The results from numerical study deviated by less than 0.1% when compared with that from the theoretical model.en_US
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectGable-roofed sheden_US
dc.subjectThermal discomforten_US
dc.subjectPassive cooling techniquesen_US
dc.subjectNumerical analysisen_US
dc.subjectLife cycle costen_US
dc.titleThermal comfort inside a gable-roofed metallic shed in a higher educational institution: a case study and detailed analysisen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.1093/ijlct/ctae115en_US
dc.identifier.volume19en_US
dc.identifier.startpage1660en_US
dc.identifier.endpage1673en_US
dc.relation.journalInternational Journal of Low-Carbon Technologiesen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster