• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Thermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change material

Thumbnail

View/Open

Full Text / Tam Metin (1.784Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2020

Author

Saxena, Abhishek
Agarwal, Nitin
Cüce, Erdem

Metadata

Show full item record

Citation

Saxena, A., Agarwal, N. & Cüce, E. (2020). Thermal performance evaluation of a solar air heater integrated with helical tubes carrying phase change material. Journal of Energy Storage, 30, 101406. https://doi.org/10.1016/j.est.2020.101406

Abstract

In this present work, the efforts have been made to improve the efficiency of solar air heater (SAH). For this, total two models have been developed. There is one reference model SAH-A and one modified model SAH-B which is integrated with paraffin wax as a low cost energy storage material. Furthermore, model SAH-B is further modified into a new model SAH-C which is integrated with a specific mixture of paraffin wax and Granular coarbon powder (GCP). For better heat storage capacity of the aforesaid energy materials, helical tube of copper made has been considered as a container. Both the models of air heater (SAH-B and SAH-C) have been experimentally tested on natural and forced convection under the climatic conditions of Moradabad city, India. Results show that SAH- C is better over SAH-A and SAH-B in performance comparison. Thermal efficiency of SAH-C is found to be 79.10%, whereas it is found around 57.41% for SAH-B and around 50% for SAH-A. the other major parameter is heat transfer coefficient and for SAH-C it is found to be 411.05 W/m(2)K, whereas it is found around 389 W/m 2 K for SAH-B and around 249.19 W/m(2)K for SAH-A. the maximum exhaust temperature of SAH-C is reported to be 52.5 degrees C, whereas it is observed around 46.9 degrees C for SAH-B and about to be 44.7 degrees C for SAH-A. the main parameters of the present work summarizes that the model SAH-C is an economic and optimum model for space heating, timber seasoning, drying operations etc. the total cost of the best configured SAH-C model is only $67.

Source

Journal of Energy Storage

Volume

30

URI

https://doi.org/10.1016/j.est.2020.101406
https://hdl.handle.net/11436/1057

Collections

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.