• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Diagnostic value of dual-energy ct iodine mapping in differentiating malignant and benign cervical lymphadenopathies

View/Open

Full Text / Tam Metin (636.0Kb)

Access

info:eu-repo/semantics/closedAccess

Date

2025

Author

Başaran, Mustafa
Çeliker, Fatma Beyazal
Çeliker, Metin
Panç, Kemal
Gürün, Enes

Metadata

Show full item record

Citation

Başaran, M., Çeliker, F. B., Çeliker, M., Panç, K., & Gürün, E. (2025). Diagnostic Value of Dual‐Energy CT Iodine Mapping in Differentiating Malignant and Benign Cervical Lymphadenopathies. Journal of Clinical Ultrasound, 53(6), 1296-1303. https://doi.org/10.1002/jcu.24014

Abstract

Purpose: To evaluate the diagnostic accuracy of Dual-Energy Computed Tomography (DECT) in distinguishing malignant from benign cervical lymph nodes in neck carcinoma based on iodine concentration and normalized spectral attenuation (Hounsfield Unit, HU) values. Methods: Retrospective DECT scan analysis was performed on 52 neck carcinoma patients, analyzing 52 metastatic and 28 reactive lymph nodes. Iodine concentration (mg/mL) and spectral HU values were measured with circular regions of interest on iodine maps. Metastatic nodes included 27 from squamous cell carcinoma (SCC), 19 from lymphoma, and 6 from papillary thyroid carcinoma (PTC). Results: Metastatic lymph nodes had lower iodine levels than reactive nodes (1.45 vs. 1.85 mg/mL, p = 0.011). No significant difference in spectral HU values was found (117 vs. 111 HU, p = 0.328). An iodine threshold of 1.62 mg/mL demonstrated 71% sensitivity and 77% specificity for detecting malignancy (AUC = 0.673, 95% CI: 0.54–0.80, p = 0.011). SCC metastases had lower iodine levels than reactive nodes (1.33 vs. 1.85 mg/mL, p < 0.001), while PTC metastases had higher levels (2.39 vs. 1.85 mg/mL, p = 0.038). Conclusion: DECT iodine quantification improves the detection of cervical lymph node metastases, particularly in cases with equivocal size criteria. Incorporating iodine measurements with tumor type knowledge improves diagnostic accuracy, aiding in prognosis and treatment planning.

Source

Journal of Clinical Ultrasound

Volume

53

Issue

6

URI

https://doi.org/10.1002/jcu.24014
https://hdl.handle.net/11436/10941

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [6273]
  • TF, Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [1245]
  • TF, Dahili Tıp Bilimleri Bölümü Koleksiyonu [1629]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.