Basit öğe kaydını göster

dc.contributor.authorUygun, Ahmet Demirhan
dc.contributor.authorGündoğdu, Eyüp Candaş
dc.contributor.authorArslan, Hakan
dc.contributor.authorErsoy, İbrahim
dc.date.accessioned2020-12-19T19:48:26Z
dc.date.available2020-12-19T19:48:26Z
dc.date.issued2017
dc.identifier.citationUygun, A. D., Gündoğdu, E. C., Arslan, H., & Ersoy, İ. (2017). Efficacy of XP-endo finisher and TRUShape 3D conforming file compared to conventional and ultrasonic irrigation in removing calcium hydroxide. Australian endodontic journal : the journal of the Australian Society of Endodontology Inc, 43(2), 89–93. https://doi.org/10.1111/aej.12176en_US
dc.identifier.issn1329-1947
dc.identifier.issn1747-4477
dc.identifier.urihttps://doi.org/10.1111/aej.12176
dc.identifier.urihttps://hdl.handle.net/11436/2077
dc.descriptionWOS: 000409198000005en_US
dc.descriptionPubMed: 27862702en_US
dc.description.abstractThe aim of this study was to compare the efficacy of the XP-endo Finisher and TRUShape 3D Conforming File to conventional and ultrasonic irrigation techniques for removing calcium hydroxide from artificially created grooves on root canals. the study used 32 human mandibular premolar teeth, which were decoronated and instrumented up to ProTaper Universal F5 (Dentsply Maillefer; Ballagiues, Switzerland). the teeth were split longitudinally, two standardised grooves were prepared in the apical and coronal portions and filled with calcium hydroxide. Each tooth was reassembled with wax. the samples were stored at 100% humidity at 37 degrees C for 1 week, after which the specimens were grouped and irrigated using needle irrigation, ultrasonic irrigation, XP-endo Finisher via continuous irrigation or TRUShape 3D Conforming File via continuous irrigation. Two calibrated observers scored the amount of calcium hydroxide remaining, and the data were statistically analysed using the Kruskal-Wallis and Mann-Whitney U-tests, (P < 0.05). Needle irrigation had the poorest scores (P <.001), while the XP-endo Finisher, TRUShape 3D Conforming File via continuous irrigation and ultrasonic irrigation groups had similar results in removing calcium hydroxide.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCalcium hydroxideen_US
dc.subjectTRUshape 3D conforming Fileen_US
dc.subjectUltrasonic irrigationen_US
dc.subjectXP-endo finisheren_US
dc.titleEfficacy of XP-endo finisher and TRUShape 3D conforming file compared to conventional and ultrasonic irrigation in removing calcium hydroxideen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorUygun, Ahmet Demirhan
dc.identifier.doi10.1111/aej.12176
dc.identifier.volume43en_US
dc.identifier.issue2en_US
dc.identifier.startpage89en_US
dc.identifier.endpage93en_US
dc.relation.journalAustralian Endodontic Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster