Basit öğe kaydını göster

dc.contributor.authorYılmaz Rakıcı, Sema
dc.contributor.authorÇınar, Yunus
dc.contributor.authorEren, Mehmet
dc.date.accessioned2020-12-19T19:49:06Z
dc.date.available2020-12-19T19:49:06Z
dc.date.issued2017
dc.identifier.citationYılmaz Rakıcı, S., Çınar, S. & Eren, M. (2017). Total Scalp Irradiation: The Comparison of Five Different Plans Using Volumetric Modulated Arc Therapy-Simultaneous Integrated Boost (VMAT-SIB) Technique. Turk Onkoloji Dergisi-Turkish Journal of Oncology, 32(3), 106-115. https://doi.org/10.5505/tjo.2017.1609en_US
dc.identifier.issn1300-7467
dc.identifier.urihttps://doi.org/10.5505/tjo.2017.1609
dc.identifier.urihttps://hdl.handle.net/11436/2220
dc.descriptionRakici, Sema Yilmaz/0000-0002-5543-9761en_US
dc.descriptionWOS: 000424786500004en_US
dc.description.abstractOBJECTIVE the aim of this study was to show that the optimum dosage can be delivered to the target organs at risk (OAR) by radiotherapy, which becomes more complicated because of technical difficulties arising from irregular, convex, and complex geometrical structure of the target, such as scalp irradiation, and because of situations resulting from the necessity of bolus of the lesion and immobilization as well as the proximity to neighboring critical organs using the VMAT-SIB technique. METHODS Five different VMAT-SIB schemes were designed using the Varian Trilogy IX linear accelerator (Varian Medical Systems) for total scalp irradiation and bilateral neck irradiation. These different VMAT scehemes were compared with respect to a dose volume histogram of obtained data, homogeneity, indices, conformity index, OAR, and doses of target volumes. RESULTS the patient-designed bolus plan 1 with two isocenters was chosen as the most appropriate plan. Plans 2, 3, 4, and 5 were inappropriate plans because the application of the virtual bolus in plan 2 was difficult, plan 3 with one isocenter was unacceptable with respect to the value of conformity index, plan 4 with three isocenters had a matching field, and plan 5 in which different priority values were used had an increase in OAR doses. CONCLUSION VMAT-SIB can be preferred as an appropriate radiotherapy technique as it can provide optimum and allowable OAR doses in tumors requiring an intensive treatment planning effort.en_US
dc.language.isoengen_US
dc.publisherKare Publen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAgiosarcoma of the Scalpen_US
dc.subjectRadiotherapyen_US
dc.subjectVMATen_US
dc.titleTotal scalp irradiation: the comparison of five different plans using volumetric modulated arc therapy-simultaneous integrated boost (VMAT-SIB) techniqueen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorYılmaz Rakıcı, Sema
dc.contributor.institutionauthorÇınar, Yunus
dc.contributor.institutionauthorEren, Mehmet
dc.identifier.doi10.5505/tjo.2017.1609
dc.identifier.volume32en_US
dc.identifier.issue3en_US
dc.identifier.startpage106en_US
dc.identifier.endpage115en_US
dc.ri.editoaen_US
dc.relation.journalTurk Onkoloji Dergisi-Turkish Journal of Oncologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US