Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss?

Thumbnail

View/Open

Full Text / Tam Metin (386.4Kb)

Access

info:eu-repo/semantics/openAccess

Date

2016

Author

Terzi, Suat
Dursun, Engin
Özgür, Abdulkadir
Coşkun, Zerrin Özergin
Erdivanlı, Özlem Çelebi
Birinci, Mehmet
Demirci, Münir

Metadata

Show full item record

Citation

Terzi, S., Dursun, E., Ozgur, A., Coskun, Z.O., Erdivanli, O.C., Ozlem, C., Birinci, M., Demirci, M. (2016). Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss?. Indian Journal of Otology, 22(3), 213-216. https://doi.org/10.4103/0971-7749.187982

Abstract

Objectives: To investigate possible sensorineural hearing loss created by the use of a cold light source in patients undergoing endoscopic tympanoplasty surgery. Materials and Methods: the medical records of 203 patients, who underwent endoscopic Type 1 tympanoplasty surgery in our ear, nose, and throat clinic between 2012 and 2015, were checked retrospectively. Ninety-one patients were male and 112 were female, and their mean age was 34.4 +/- 11.2 years. Results of audiometric measurements performed during the preoperative period and repeated 1 and 3 months postsurgery were compared to each other. Results: the mean duration of the operations was determined to be 52.4 +/- 9.1 min. in addition, average preoperative bone-conduction was 11.4 +/- 7.4 dB nHL. However, it was 9.57 +/- 7.1 dB nHL and 9.51 +/- 7.4 dB nHL, respectively, in the 1st and 3rd postoperative months. Levels of postoperative average bone-conduction at the 1st and 3rd month, as well as the thresholds of bone-conduction at 500, 1000, and 2000 Hz, were significantly lower than the preoperative results (P < 0.05). However, there was not a remarkable difference at 4000 Hz (P > 0.05). Conclusion: Based on our findings, the increased heat generated by the use of a cold light source during an endoscopic tympanoplasty surgery is unlikely to cause the development of sensorineural hearing loss.

Source

Indian Journal of Otology

Volume

22

Issue

3

URI

https://doi.org/10.4103/0971-7749.187982
https://hdl.handle.net/11436/2455

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • TF, Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [1216]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.