Basit öğe kaydını göster

dc.contributor.authorTerzi, Suat
dc.contributor.authorDursun, Engin
dc.contributor.authorÖzgür, Abdulkadir
dc.contributor.authorCoşkun, Zerrin Özergin
dc.contributor.authorErdivanlı, Özlem Çelebi
dc.contributor.authorBirinci, Mehmet
dc.contributor.authorDemirci, Münir
dc.date.accessioned2020-12-19T19:50:40Z
dc.date.available2020-12-19T19:50:40Z
dc.date.issued2016
dc.identifier.citationTerzi, S., Dursun, E., Ozgur, A., Coskun, Z.O., Erdivanli, O.C., Ozlem, C., Birinci, M., Demirci, M. (2016). Can use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss?. Indian Journal of Otology, 22(3), 213-216. https://doi.org/10.4103/0971-7749.187982en_US
dc.identifier.issn0971-7749
dc.identifier.issn2249-9520
dc.identifier.urihttps://doi.org/10.4103/0971-7749.187982
dc.identifier.urihttps://hdl.handle.net/11436/2455
dc.descriptionWOS: 000387945900015en_US
dc.description.abstractObjectives: To investigate possible sensorineural hearing loss created by the use of a cold light source in patients undergoing endoscopic tympanoplasty surgery. Materials and Methods: the medical records of 203 patients, who underwent endoscopic Type 1 tympanoplasty surgery in our ear, nose, and throat clinic between 2012 and 2015, were checked retrospectively. Ninety-one patients were male and 112 were female, and their mean age was 34.4 +/- 11.2 years. Results of audiometric measurements performed during the preoperative period and repeated 1 and 3 months postsurgery were compared to each other. Results: the mean duration of the operations was determined to be 52.4 +/- 9.1 min. in addition, average preoperative bone-conduction was 11.4 +/- 7.4 dB nHL. However, it was 9.57 +/- 7.1 dB nHL and 9.51 +/- 7.4 dB nHL, respectively, in the 1st and 3rd postoperative months. Levels of postoperative average bone-conduction at the 1st and 3rd month, as well as the thresholds of bone-conduction at 500, 1000, and 2000 Hz, were significantly lower than the preoperative results (P < 0.05). However, there was not a remarkable difference at 4000 Hz (P > 0.05). Conclusion: Based on our findings, the increased heat generated by the use of a cold light source during an endoscopic tympanoplasty surgery is unlikely to cause the development of sensorineural hearing loss.en_US
dc.language.isoengen_US
dc.publisherMedknow Publications & Media Pvt Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAudiological surgical proceduresen_US
dc.subjectCold light sourcesen_US
dc.subjectTympanoplastyen_US
dc.titleCan use of a cold light source in endoscopic middle ear surgery cause sensorineural hearing loss?en_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorTerzi, Suat
dc.contributor.institutionauthorDursun, Engin
dc.contributor.institutionauthorÖzgür, Abdulkadir
dc.contributor.institutionauthorCoşkun, Zerrin Özergin
dc.contributor.institutionauthorErdivanlı, Özlem Çelebi
dc.contributor.institutionauthorBirinci, Mehmet
dc.contributor.institutionauthorDemirci, Münir
dc.identifier.doi10.4103/0971-7749.187982
dc.identifier.volume22en_US
dc.identifier.issue3en_US
dc.identifier.startpage213en_US
dc.identifier.endpage216en_US
dc.relation.journalIndian Journal of Otologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster