Electrode prepared with combination of different conductive polymers for hydroquinone determination in river water

Thumbnail

View/Open

Full Text / Tam Metin (381.2Kb)

Access

info:eu-repo/semantics/openAccess

Date

2016

Author

Ülker, Emine
Kavanoz, Muammer

Metadata

Show full item record

Citation

Ülker, E., & Kavanoz, M. (2016). Electrode Prepared with Combination of Different Conductive Polymers for Hydroquinone Determination in River Water. Acta chimica Slovenica, 63(1), 47–54. https://doi.org/10.17344/acsi.2015.1897

Abstract

Modified electrode based on combination of different conductive polymers (polyaniline -poly(3-methylthiophene) poly( 3,3'-diaminobenzidine) (PANI - P3MT - PDAB)) was previously synthesized in dichloromethane containing HClO4 and tetrabutylammoniumperchlorate (TBAP) as supporting electrolyte. Herein, the determination of hydroquinone (HQ) with amperometric I-t method over this modified and its homopolymers coated electrode was successfully carried out in river water as a real sample and in solution consisting of NaHSO4/Na2SO4 (pH 2.0). For this method, potentials between 0.45 V and 0.65 V were applied and the best analytical response was obtained at 0.55 V using this modified electrode when compared to its homopolymers. the limit of detection (LOD), limit of quantification (LOQ), the linear dynamic range and regression coefficient (R-2) were found as 1.31 x 10(-4) mM, 4.37 x 10(-4) mM, 4.37 x 10(-4)-95.0 mM and 0.998, respectively. These results were compared to homopolymers coated and uncoated Pt electrodes. For checking on the accuracy of the developed method and the matrices interference, determination of HQ was performed in artificially contaminated river water samples with HQ concentration of 5.0 mM and 10.0 mM using this modified electrode and recovery values were calculated as 100.6% and 100.1%, respectively.

Source

Acta Chimica Slovenica

Volume

63

Issue

1

URI

https://hdl.handle.net/11436/2682

Collections

  • FEF, Kimya Bölümü Koleksiyonu [476]
  • PubMed İndeksli Yayınlar Koleksiyonu [2443]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.