Basit öğe kaydını göster

dc.contributor.authorÜlker, Emine
dc.contributor.authorKavanoz, Muammer
dc.date.accessioned2020-12-19T19:56:28Z
dc.date.available2020-12-19T19:56:28Z
dc.date.issued2015
dc.identifier.citationUlker, E., Kavanoz, M. (2015). Determination of epinephrine in human serum using a Pt electrode modified by polyaniline-poly(3-methylthiophene)-poly(3,3 '-diaminobenzidine). Canadian Journal of Chemistry, 93(11), 1239-1244. https://doi.org/10.1139/cjc-2015-0207en_US
dc.identifier.issn0008-4042
dc.identifier.issn1480-3291
dc.identifier.urihttps://doi.org/10.1139/cjc-2015-0207
dc.identifier.urihttps://hdl.handle.net/11436/2740
dc.descriptionWOS: 000364158200012en_US
dc.description.abstractA Pt electrode modified by polyaniline-poly(3-methylthiophene)-poly(3,3'-diaminobenzidine) was used for amperometric determination of epinephrine in a solution of NaHSO4/Na2SO4 (pH 2.0). For these studies, potentials between 0.40 and 0.50 V were applied, and the best response was obtained at 0.45 V. the limit of detection, limit of quantification, and the linear dynamic range were 1.23 x 10(-4), 4.10 x 10(-4), and 4.10 x 10(-4) to 100.0 mmol L-1, respectively. These results were compared with determinations using Pt electrodes that were coated and uncoated with homopolymers. To check the accuracy of the developed method and the matrices interference, determination of epinephrine was performed in human serum samples using this modified electrode. the epinephrine concentrations were adjusted to 1.0 and 5.0 mmol L-1, and recovery values were calculated as 100.4% and 96.8%, respectively. It is significant that the determination of epinephrine was carried out at a lower potential (0.45 V) than the oxidation potential of epinephrine (0.65 V) without any matrix effect.en_US
dc.description.sponsorshipScientific and Technological Research Council of Turkey (TUBITAK)Turkiye Bilimsel ve Teknolojik Arastirma Kurumu (TUBITAK) [111T445]; Recep Tayyip Erdogan UniversityRecep Tayyip Erdogan University; Unit of Scientific Research [2013.102.02.3]en_US
dc.description.sponsorshipWe are grateful for the financial support of the Scientific and Technological Research Council of Turkey (TUBITAK) (Project No. 111T445) and Recep Tayyip Erdogan University, Unit of Scientific Research (Project No. 2013.102.02.3). We thank Dr. Seluk Demir (Recep Tayyip Erdogan University, Faculty of Sciences & Arts, Department of Chemistry, Rize, Turkey) for improving the language of this manuscript.en_US
dc.language.isoengen_US
dc.publisherCanadian Science Publishing, Nrc Research Pressen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectEpinephrineen_US
dc.subjectPolyanilineen_US
dc.subjectPoly(3-methylthiophene)en_US
dc.subjectPoly(3,3 '-diaminobenzidine)en_US
dc.subjectAmperometric determinationen_US
dc.titleDetermination of epinephrine in human serum using a Pt electrode modified by polyaniline-poly(3-methylthiophene)-poly(3,3 '-diaminobenzidine)en_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Kimya Bölümüen_US
dc.contributor.institutionauthorÜlker, Emine
dc.contributor.institutionauthorKavanoz, Muammer
dc.identifier.doi10.1139/cjc-2015-0207
dc.identifier.volume93en_US
dc.identifier.issue11en_US
dc.identifier.startpage1239en_US
dc.identifier.endpage1244en_US
dc.relation.journalCanadian Journal of Chemistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster