Basit öğe kaydını göster

dc.contributor.authorDuran, Celal
dc.contributor.authorÖzdeş, Duygu
dc.contributor.authorAkçay, Hakkı Türker
dc.contributor.authorSerencam, Hüseyin
dc.contributor.authorTüfekçi, Mehmet
dc.date.accessioned2020-12-19T19:57:59Z
dc.date.available2020-12-19T19:57:59Z
dc.date.issued2015
dc.identifier.citationDuran, C., Ozdes, D., Akcay, H.T., Serencam, H., Tufekci, M. (2015). Simultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determination. Desalination and Water Treatment, 53(2), 390-397. https://doi.org/10.1080/19443994.2013.839401en_US
dc.identifier.issn1944-3994
dc.identifier.issn1944-3986
dc.identifier.urihttps://doi.org/10.1080/19443994.2013.839401
dc.identifier.urihttps://hdl.handle.net/11436/2911
dc.descriptionAKCAY, Hakki Turker/0000-0002-8502-9608; OZDES, Duygu/0000-0002-8692-2676en_US
dc.descriptionWOS: 000347687800013en_US
dc.description.abstractIn the present study, Cd(II), Co(II), and Ni(II) ions were separated and preconcentrated via carrier element-free coprecipitation (CEFC) method by using an organic coprecipitating agent, 1,2-bis-(2-tosyl ethoxy) benzene (BTEB), prior to their flame atomic absorption spectrometric (FAAS) detections. the experimental conditions were optimized in terms of pH of the aqueous solution, BTEB amount, standing time, centrifugation rate and time, and sample volume. Under the optimum experimental conditions, the detection limits for Cd(II), Co(II), and Ni(II) ions were found to be 0.13, 0.67, and 0.46 mu g L-1, respectively, and the relative standard deviations for the analyte ions were found to be lower than 4.0%. the accuracy of the method was tested by analyzing certified reference material and spike tests. the method was applied to determine the levels of Cd(II), Co(II), and Ni(II) ions in sea and stream water, macaroni, red lentil, and cracked wheat samples.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFlame atomic absorption spectrometryen_US
dc.subjectSeparationen_US
dc.subjectPreconcentrationen_US
dc.subjectHeavy metalsen_US
dc.subjectCarrier element free coprecipitationen_US
dc.titleSimultaneous separation and preconcentration of Cd(II), Co(II), and Ni(II) ions in environmental samples by carrier element-free coprecipitation method prior to their flame atomic absorption spectrometric determinationen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Kimya Bölümüen_US
dc.contributor.institutionauthorAkçay, Hakkı Türker
dc.identifier.doi10.1080/19443994.2013.839401
dc.identifier.volume53en_US
dc.identifier.issue2en_US
dc.identifier.startpage390en_US
dc.identifier.endpage397en_US
dc.relation.journalDesalination and Water Treatmenten_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster