dc.date.issued2017
dc.identifier.citationAlkurt, M., Duymus, Z. Y., Gundogdu, M., & Karadas, M. (2017). Comparison of temperature change among different adhesive resin cement during polymerization process. Journal of Indian Prosthodontic Society, 17(2), 183–188. https://doi.org/10.4103/jips.jips_327_16en_US
dc.identifier.issn0972-4052
dc.identifier.urihttps://doi.org/10.4103/jips.jips_327_16
dc.identifier.urihttps://hdl.handle.net/11436/4383
dc.description.abstractPurpose: The aim of this study was to assess the intra-pulpal temperature changes in adhesive resin cements during polymerization. Materials and Methods: Dentin surface was prepared with extracted human mandibular third molars. Adhesive resin cements (Panavia F 2.0, Panavia SA, and RelyX U200) were applied to the dentin surface and polymerized under IPS e.max Press restoration. K-type thermocouple wire was positioned in the pulpal chamber to measure temperature change (n = 7). The temperature data were recorded (0.0001 sensible) and stored on a computer every 0.1 second for sixteen minutes. Differences between the baseline temperature and temperatures of various time points (2, 4, 6, 8, 10, 12, 14, and 16 minute) were determined and mean temperature changes were calculated. At various time intervals, the differences in temperature values among the adhesive resin cements were analyzed by two-way ANOVA and post-hoc Tukey honestly test (? = 0.05). Results: Significant differences were found among the time points and resin cements (P < 0.05). Temperature values of the Pan SA group were significantly higher than Pan F and RelyX (P < 0.05). Conclusion: Result of the study on self-adhesive and self-etch adhesive resin cements exhibited a safety intra-pulpal temperature change. © 2017 The Journal of Indian Prosthodontic Society | Published by Wolters Kluwer ?.Medknow.en_US
dc.language.isoengen_US
dc.publisherMedknow Publicationsen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdhesiveen_US
dc.subjectPolymerizationen_US
dc.subjectResin cementen_US
dc.subjectTemperature changeen_US
dc.subjectThermocoupleen_US
dc.titleComparison of temperature change among different adhesive resin cement during polymerization processen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorAlkurt, Murat
dc.contributor.institutionauthorDuymuş, Zeynep Yeşil
dc.contributor.institutionauthorKaradaş, Muhammet
dc.identifier.doi10.4103/jips.jips_327_16
dc.identifier.volume17en_US
dc.identifier.issue2en_US
dc.identifier.startpage183en_US
dc.identifier.endpage188en_US
dc.relation.journalJournal of Indian Prosthodontist Societyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster