• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Non-enzymatic phenol determination in river water over modified electrode with poly(3-methylthiophene)

View/Open

Tam Metin / Full Text (1.194Mb)

Access

info:eu-repo/semantics/openAccess

Date

2016

Author

Kavanoz, Muammer
Bük, Ufuk
Ülker, Emine

Metadata

Show full item record

Citation

Kavanoz, M., Bük, U. & Ülker, E. (2016). Non-enzymatic phenol determination in river water over modified electrode with poly(3-methylthiophene). Hittite Journal of Science and Engineering, 3(1), 35-40.

Abstract

T his paper describes non-enzymatic phenol determination using poly(3methylthiophene) coated Pt electrode. Modified electrode was prepared on Pt disc surface in dichloromethane medium containing 500 mM 3-methylthiophene (3MT) and 100 mM tetrabuthylammonium perchlorate (TBAP). This electrode was used for amperometric determination of phenol in NaHSO4 / Na2SO4 (SBS) solution at pH 2.0. For this purpose, 0.70, 0.80 and 0.90 V potentials were applied and results were compared. Limit of detection and linear range were found as 4.22x10-5 and 1.41x104 - 4.00 mM (with R2=0.9932) at 0.90 V working potential, respectively. Repeatability of method was tested by using at least three modified electrode for 0.5, 1.0 and 2.0 mM phenol concentrations and relative standard deviation (RSD were found as 2.49%, 1.92% and 2.75%, respectively. To test the accuracy of method and matrix effect, phenol determination was carried out for 1.0 and 2.0 mM phenol concentrations in artificially contaminated river water samples at optimum condition and recovery values were found as 96.44% and 99.60%, respectively. Proposed method was found as simple, rapid and economic for phenol determination.

Source

Hittite Journal of Science and Engineering

Volume

3

Issue

1

URI

https://app.trdizin.gov.tr/makale/TWpFMk5UazBOQT09
https://hdl.handle.net/11436/5929

Collections

  • FEF, Kimya Bölümü Koleksiyonu [478]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [2844]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.