Basit öğe kaydını göster

dc.contributor.authorCüce, Erdem
dc.contributor.authorSaxena, Abhishek
dc.contributor.authorCüce, Pınar Mert
dc.contributor.authorŞen, Harun
dc.contributor.authorGuo, Shaopeng
dc.contributor.authorSudhakar, K.
dc.date.accessioned2022-08-16T07:29:54Z
dc.date.available2022-08-16T07:29:54Z
dc.date.issued2021en_US
dc.identifier.citationCuce, E., Saxena, A., Cuce, M.P., Sen, H., Guo, S. & Sudhakar, K. (2021). Performance assessment of solar chimney power plants with the impacts of divergent and convergent chimney geometry. International journal of Low-Carbon Technologies, 16(3), 704-714. https://doi.org/10.1093/ijlct/ctaa097en_US
dc.identifier.issn1748-1317
dc.identifier.issn1748-1325
dc.identifier.urihttps://doi.org/10.1093/ijlct/ctaa097
dc.identifier.urihttps://hdl.handle.net/11436/6358
dc.description.abstractInfluence of area ratio (AR) on main performance parameters of solar chimney power plants (SCPPs) is investigated through a justified 3D axisymmetric CFD model. Geometric characteristics of Manzanares pilot plant (MPP) are taken into consideration for the numerical model. AR is varied from 0.5 to 10 to cover both concave and convex (convergent and divergent) solar chimney designs. Following the accuracy verification of the CFD results and proving mesh-independent solution, main performance oriented parameters are assessed as a function of AR such as velocity, temperature and pressure distribution within MPP, temperature rise of air in collector, mass flow rate of air around the turbine area, dynamic pressure difference across the turbine, minimum static pressure in the entire plant, power output and system efficiency. The results reveal that AR plays a vital role in performance figures of MPP. Mass flow rate of air (<(m)over dot>) is found to be 1122.1 kg/s for the reference geometry (AR = 1), whereas it is 1629.1 kg/s for the optimum AR value of 4. System efficiency (eta) is determined to be 0.29% for the reference case; however, it is enhanced to 0.83% for the AR of 4.1. MPP can generate 54.3 kW electrical power in its current design while it is possible to improve this figure to 168.5 kW with the optimal AR value.en_US
dc.language.isoengen_US
dc.publisherOxford University Pressen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSolar chimneyen_US
dc.subjectDivergent and convergent chimneyen_US
dc.subjectMaximum velocityen_US
dc.subjectPower outputen_US
dc.subjectSystem efficiencyen_US
dc.subjectChimney designen_US
dc.titlePerformance assessment of solar chimney power plants with the impacts of divergent and convergent chimney geometryen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.contributor.institutionauthorCüce, Pınar Mert
dc.contributor.institutionauthorŞen, Harun
dc.identifier.doi10.1093/ijlct/ctaa097en_US
dc.identifier.volume16en_US
dc.identifier.issue3en_US
dc.identifier.startpage704en_US
dc.identifier.endpage714en_US
dc.relation.journalInternational journal of Low-Carbon Technologiesen_US