• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Experimental investigation and force analysis of flat-plate type pulsating heat pipes having ternary mixtures

Thumbnail

View/Open

Full Text / Tam Metin (12.24Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2021

Author

Markal, Burak
Varol, Ramazan

Metadata

Show full item record

Citation

Markal, B. & Varol, R. (2021). Experimental investigation and force analysis of flat-plate type pulsating heat pipes having ternary mixtures. International Communications in Heat and Mass Transfer, 121, 105084. https://doi.org/10.1016/j.icheatmasstransfer.2020.105084

Abstract

Comprehensive experiments are conducted to analyze complex heat transfer characteristics and flow nature of a flat plate closed loop pulsating heat pipe charged with ternary mixtures. Consecutive channels of the heat pipe have different cross sections. Fluids forming the mixtures are deionized water (W), methanol (M) and pentane (P). Effects of different volume mixing ratios of these fluids (W:M:P = 1:1:1, 1:2:3 and 1:3:2) on thermal performance are evaluated comparatively with pure counterparts. Experimental range also covers other key parameters: filling ratio (30%, 50% and 70%), inclination angle (0 degrees and 901 and heat input. Flow patterns and bubble-liquid dynamics are examined. Results show that medium filling ratio of 50% presents optimum performance for all mixing ratios. At vertical orientation, ternary mixtures, especially the ones having higher content of pentane or methanol (1:2:3 and 1:3:2), show significantly better thermal characteristics compared to pure fluids. However, heat pipes charged with ternary mixtures are highly dependent on gravity; such that flat plate closed loop pulsating heat pipe having mixtures cannot operate in horizontal position. In usage of ternary mixtures, liquid droplets flowing down through channels are observed; this is called as rewetting phenomenon enhancing thermal performance. Force analysis characterizing thermo-fluid-geometric coupling is conducted

Source

International Communications in Heat and Mass Transfer

Volume

121

URI

https://doi.org/10.1016/j.icheatmasstransfer.2020.105084
https://hdl.handle.net/11436/6498

Collections

  • Enerji Sistemleri Mühendisliği Bölümü Koleksiyonu [117]
  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.