Basit öğe kaydını göster

dc.contributor.authorAltuntaş, Derya Bal
dc.contributor.authorKuralay, Filiz
dc.date.accessioned2022-10-03T07:32:49Z
dc.date.available2022-10-03T07:32:49Z
dc.date.issued2021en_US
dc.identifier.citationAltuntas, D.B. & Kuralay, F. (2021). MoS2/Chitosan/GOx-Gelatin modified graphite surface: Preparation, characterization and its use for glucose determination. Materials Science and Engineering: B, 270, 115215. https://doi.org/10.1016/j.mseb.2021.115215en_US
dc.identifier.issn0921-5107
dc.identifier.issn1873-4944
dc.identifier.urihttps://doi.org/10.1016/j.mseb.2021.115215
dc.identifier.urihttps://hdl.handle.net/11436/6619
dc.description.abstractGraphene-like new generation of two dimensional (2D) nanomaterials, in particular the family of transition metal dichalcogenides (TMDCs) have been attracting a wide range of research interest. Among the family of TMDCs, molybdenum disulfide (MoS2) has been the most used one for biosensor applications. In this work, we detail the preparation of MoS2/chitosan composite modified pencil graphite electrode (MoS2/Chitosan/PGE) and its use as glucose biosensor after the modified electrode were immobilized with glucose oxidase (GOx)-gelatin (MoS2/Chitosan/GOx-Gelatin/PGE). This electrode was compared with the unmodified electrode in terms of electrochemical performance. Superior electrochemical responses were achieved including good electroactivity and sensitive glucose biosensing. For the MoS2/Chitosan/GOx-Gelatin modified PGE, a linear glucose concentration range was obtained from 10 mu M to 800 mu M with the equation of y = 0.0008x + 0.0547 (R2 = 0.9992) and a limit of detection (LOD) value of 3.18 mu M. The relative standard deviation (RSD%) was calculated as 3.77% at 200 mu M glucose (n = 5). The biosensor was tested in the presence of dopamine and ascorbic acid and our results presented the high selectivity of this novel MoS2/Chitosan/GOx-Gelatin modified PGE as a glucose biosensor.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subject2D materialsen_US
dc.subjectChitosanen_US
dc.subjectGlucose biosensoren_US
dc.titleMoS2/Chitosan/GOx-Gelatin modified graphite surface: Preparation, characterization and its use for glucose determinationen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Biyomühendislik Bölümüen_US
dc.contributor.institutionauthorAltuntaş, Derya Bal
dc.identifier.doi10.1016/j.mseb.2021.115215en_US
dc.identifier.volume270en_US
dc.identifier.startpage115215en_US
dc.relation.journalMaterials Science and Engineering: Ben_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster