• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Evaluation of monomer elution, microhardness, and roughness of experimental dental composite resins prepared from Bis-EFMA, a novel monomer system

Thumbnail

View/Open

Full Text / Tam Metin (2.117Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2021

Author

Hatipoğlu, Ömer
Turumtay, Emine Akyüz
Saygın, Ayşegül Göze

Metadata

Show full item record

Citation

Hatipoglu, O., Turumtay, E.A. & Saygin, A.G. (2021). Evaluation of monomer elution, microhardness, and roughness of experimental dental composite resins prepared from Bis-EFMA, a novel monomer system. Polymer Composites, 43(1), 584-592. https://doi.org/10.1002/pc.26401

Abstract

This study aimed to compare the monomer elution, microhardness, and roughness of experimental resin-based composites (RBCs) prepared from a novel monomer system derived from 9,9-Bis[4-(2-hydroxyethoxy)phenyl]fluorene) (Bis-EFMA), bisphenol A-glycidyl methacrylate (Bis-GMA), and urethane dimethacrylate (UDMA) with each other, also with a commercial RBC, 3 M ESPE FiltekTM Z250 (FZ). Experimental Bis-EFMA (ET), Bis-GMA (BT), and UDMA (UT) based composites were prepared (20% Bis-EFMA or 20% Bis-GMA or 20% UDMA, and 20% triethylene glycol dimethacrylate [TEGDMA], and 60% glass filler). 60 specimens were produced (n = 5) and exposed to ethanol solution for 7 days. Then specimens were tested at baseline (T0), first (T1), third (T2), and seventh (T3) days. ET and FZ released significantly lower TEGDMA than other RBCs did (p < 0.05). BT released significantly higher TEGDMA than other RBCs did at T1 (p < 0.05). However, no significant difference was found between FZ and ET at T1 (p > 0.05). FZ exhibited the highest microhardness at all-time points; besides, the microhardness of BT was lowest at T0, while the microhardness of BT and UT was lower than that of FZ and ET at T1, T2, and T3 (p < 0.05). BT exhibited higher roughness at T2 than the UT did at T0 and T1, significantly (p < 0.05). However, no significant difference was found between the other RBCs (p > 0.05). Bis-EFMA, a novel bisphenol A-free monomer system, has the potential to be used in commercial RBCs as a substitute for Bis-GMA in terms of lower monomer elution and higher microhardness.

Source

Polymer Composites

Volume

43

Issue

1

URI

https://doi.org/10.1002/pc.26401
https://hdl.handle.net/11436/6681

Collections

  • FEF, Kimya Bölümü Koleksiyonu [476]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.