Show simple item record

dc.contributor.authorMaduru, Venkata Ramana
dc.contributor.authorShaik, Saboor
dc.contributor.authorCüce, Erdem
dc.contributor.authorKirankumar, Gorantla
dc.contributor.authorChelliah, Arumugam
dc.contributor.authorAfzal, Asif
dc.contributor.authorMohanty, Chinmay Prasada
dc.date.accessioned2023-01-10T07:50:52Z
dc.date.available2023-01-10T07:50:52Z
dc.date.issued2022en_US
dc.identifier.citationMaduru, V. R., Shaik, S. Cuce, E., Kirankumar, G., Chelliah, A., Afzal, A. & Mohanty, C.P. (2022). Analysis of effective parameters of building’s glazing on energy savings and carbon emission mitigation prospective. International Journal of Ambient Energy, 43(1), 8959-8970. https://doi.org/10.1080/01430750.2022.2111348en_US
dc.identifier.issn0143-0750
dc.identifier.urihttps://doi.org/10.1080/01430750.2022.2111348
dc.identifier.urihttps://hdl.handle.net/11436/7383
dc.description.abstractThe optimal window-to-wall-ratio of the glazing systems and the wall thickness of the building will help reduce energy consumption in the buildings. The current work explores the spectral characteristics of clear, tinted (Tinted Green & Tinted Bronze), and reflective (Reflective Bronze) glasses. Solar-optical properties of different double and triple glazing systems formed with the aforementioned glass samples using experimentally measured data. The laterite buildings modelled with three double-glazing configurations and three triple-glazing configurations at five different window-wall-ratios (20%, 40%, 60%, 80%, and 100%) have been studied for the solar heat gains, thermal loads, and daylight ingress. The model building with 0.229 m thick laterite wall and 40% TBRGW glazing had reported an annual cooling cost savings of $32.02 and carbon emission mitigation of 308.4 kg-CO2/year compared to 0.076 m thick laterite wall. The average daylight factor simulation results had concluded the adequate daylight inflow in the building interiors.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Ltd.en_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectAnnual cost-savingsen_US
dc.subjectCarbon emission mitigationsen_US
dc.subjectDaylight performanceen_US
dc.subjectDouble& triple glazing arrangementsen_US
dc.subjectLaterite stone buildingsen_US
dc.subjectWindow-to-wall-ratioen_US
dc.titleAnalysis of effective parameters of building’s glazing on energy savings and carbon emission mitigation prospectiveen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.1080/01430750.2022.2111348en_US
dc.identifier.volume43en_US
dc.identifier.issue1en_US
dc.identifier.startpage8959en_US
dc.identifier.endpage8970en_US
dc.relation.journalInternational Journal of Ambient Energyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record