Show simple item record

dc.contributor.authorShaik, Sharmas Vali
dc.contributor.authorGorantla, Kirankumar
dc.contributor.authorShaik, Saboor
dc.contributor.authorAfzal, Asif
dc.contributor.authorRajhi, Ali A
dc.contributor.authorCüce, Erdem
dc.date.accessioned2023-09-01T07:03:20Z
dc.date.available2023-09-01T07:03:20Z
dc.date.issued2023en_US
dc.identifier.citationShaik, S.V., Gorantla, K., Shaik, S., Afzal, A., Rajhi, A.A. & Cüce, E. (2023). Experimental and theoretical examination of the energy performance and CO2 emissions of room air conditioners utilizing natural refrigerant R290 as a substitute for R22. Journal of Thermal Analysis and Calorimetry. https://doi.org/10.1007/s10973-022-11888-2en_US
dc.identifier.issn1388-6150
dc.identifier.issn1588-2926
dc.identifier.urihttps://doi.org/10.1007/s10973-022-11888-2
dc.identifier.urihttps://hdl.handle.net/11436/8222
dc.description.abstractThe purpose of this research is to analyze the performance of an air conditioner that uses natural refrigerant R290 both analytically and experimentally. The feasibility of R290 for R22 air conditioner is examined thoroughly. Since the alternatives used in R22 air conditioners possess high GWPs and they are controlled by the Kyoto Protocol. The Kyoto Protocol mainly indicates that the high GWP refrigerants used in refrigeration and air conditioning sectors are classified into one among the targeted greenhouse gases. Therefore, the present work focuses on ecofriendly-refrigerant R290 as a substitute to R22. In comparison to R22, R290 has no ODP and a very low GWP. An analytical study is conducted based on the actual VCR cycle. An experimental study was conducted on the R22 air conditioner with R290 at various outdoor conditions. Test results revealed that electrical energy consumption of air conditioner with R290 was 12.30% lower compared to R22 for the lower operating conditions and it was 11.40% lower compared to R22 for the higher operating conditions. Cooling capacity of R290 compared to R22 is lower in the range of 6.37-9.24% for the test conditions studied. For the operating circumstances studied, the energy efficiency ratio of R290 is higher than R22, ranging from 2.41 to 6.77%. Compressor discharge temperature of R290 is lower in the range of 8.67-15.32 ? for all the investigated conditions. When compared to R22, CO2 emissions from air conditioners operating with R290 are lower in the range from 13.10 to 14.18%. The study revealed that R290 is a viable option to replace R22 used in air conditioners in terms of performance and environmental aspects.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCooling capacityen_US
dc.subjectCO2 emissionsen_US
dc.subjectEnergy efficiency ratioen_US
dc.subjectGWPen_US
dc.subjectR22 alternative refrigerantsen_US
dc.titleExperimental and theoretical examination of the energy performance and CO2 emissions of room air conditioners utilizing natural refrigerant R290 as a substitute for R22en_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.1007/s10973-022-11888-2en_US
dc.relation.journalJournal of Thermal Analysis and Calorimetryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Files in this item