An analysis of human error and reliability in the operation of fixed CO2 systems on cargo ships using HEART Dempster-Shafer evidence theory approach

Thumbnail

View/Open

Full Text / Tam Metin (2.924Mb)

Access

info:eu-repo/semantics/closedAccess

Date

2023

Author

Aydın, Muhammet

Metadata

Show full item record

Citation

Aydın, M. (2023). An analysis of human error and reliability in the operation of fixed CO2 systems on cargo ships using HEART Dempster-Shafer evidence theory approach. Ocean Engineering, 286, 115686. https://doi.org/10.1016/j.oceaneng.2023.115686

Abstract

CO2 fixed fire extinguishing system activation accidents may occur as a result of unintentional system activation or human error. Crew members present in the area could suffer serious consequences, including death, if CO2 gas is released into a protected compartment such as the engine room, CO2 room, or cargo area. It is therefore crucial to investigate and address the causes of such accidents. The use of Dempster-Shafer (D-S) theory and the Human Error Assessment and Reduction Technique (HEART) to the Human Reliability Analysis (HRA) of CO2 fixed fire extinguishing system activation accidents is discussed in this study. On the one hand, D-S theory allows for uncertainty-based reasoning and can be extremely advantageous, especially when analysing complex systems where there are many potential challenges. On the other hand, HEART is an organised method to examine and reduce human error in high-risk systems. Together, these techniques provide a powerful tool for identifying and addressing the underlying causes of CO2 fixed fire extinguishing system activation accidents. The study revealed that the total human error probability (HEP) for the CO2 fixed fire extinguishing system was 3.10E-01 and the reliability of human performance for the given process was 6.90E-01. The results of this paper highlight many factors such as equipment failure, inadequate training, and poor maintenance practices, as well as factors contributing to the risk of accidental system activation. By addressing these factors, the probability of CO2-fixed fire suppression system activation accidents can be significantly reduced.

Source

Ocean Engineering

Volume

286

URI

https://doi.org/10.1016/j.oceaneng.2023.115686
https://hdl.handle.net/11436/8310

Collections

  • DNZF, Deniz Ulaştırma İşletme Mühendisliği Bölümü Koleksiyonu [102]
  • Scopus İndeksli Yayınlar Koleksiyonu [5990]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.