Basit öğe kaydını göster

dc.contributor.authorCüce, Pınar Mert
dc.contributor.authorCüce, Erdem
dc.date.accessioned2023-10-11T06:42:51Z
dc.date.available2023-10-11T06:42:51Z
dc.date.issued2023en_US
dc.identifier.citationCüce, P.M. & Cüce, E. (2023). Performance Analysis of Fresnel Lens Driven Hot Water/ Steam Generator for Domestic and Industrial Use: A CFD Research. Hittite Journal of Science and Engineering, 10(1), 1-9. https://doi.org/10.17350/HJSE19030000285en_US
dc.identifier.issn2149-2123
dc.identifier.issn2148-4171
dc.identifier.urihttps://doi.org/10.17350/HJSE19030000285
dc.identifier.urihttps://hdl.handle.net/11436/8469
dc.description.abstractThis study presents the design, manufacture, and thermal performance analysis of a Fresnel lens-driven hot water/steam generator. The designed system is suitable for domestic and industrial hot water/steam usage and can be easily scaled up to meet different capacity needs. In the first step of the research, the thermal behavior of the cast plate heat exchanger driven by a Fresnel lens with a concentration ratio of 100 is investigated at different working fluid velocities (0.6, 0.8, 1.0, 1.5 and 2.0 m/s) and at different absorber surface temperatures. The outlet temperature of working fluid from the cast plate heat exchanger is determined through a 3D CFD model for each case. The capacity of the steam generator for different operating times (h = 1, 2 and 3 hours) is also evaluated. The highest working fluid temperature at the outlet of the heat exchanger is 914.8 °C for Tcp = 1000 °C and Vwf = 0.6 m/s. On the other hand, the lowest temperature is observed as 424.7 °C for Tcp = 700 °C and Vwf = 2.0 m/s. The steam capacity of the system for h = 3 hours is determined as 1696.5 and 508.9 kg in the best ( Vwf = 2.0 m/s) and worst cases ( Vwf = 0.6 m/s), respectively.en_US
dc.language.isoengen_US
dc.publisherHitit Üniversitesien_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSolar collectoren_US
dc.subjectFresnel lensen_US
dc.subjectSteam generatoren_US
dc.subjectDomestic hot wateren_US
dc.subjectThermal performanceen_US
dc.titlePerformance analysis of fresnel lens driven hot water/ steam generator for domestic and industrial use: A CFD researchen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Mimarlık Bölümüen_US
dc.contributor.institutionauthorCüce, Pınar Mert
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.17350/HJSE19030000285en_US
dc.identifier.volume10en_US
dc.identifier.issue1en_US
dc.identifier.startpage1en_US
dc.identifier.endpage9en_US
dc.relation.journalHittite Journal of Science and Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US