Basit öğe kaydını göster

dc.contributor.authorCan, Özay
dc.contributor.authorAyas, Mustafa Şinasi
dc.date.accessioned2024-02-05T13:30:28Z
dc.date.available2024-02-05T13:30:28Z
dc.date.issued2023en_US
dc.identifier.citationCan, Ö. & Ayas, M.S. (2023). Gorilla troops optimization-based load frequency control in PV-thermal power system. Neural Computing and Applications, 2023. http://doi.org/10.1007/s00521-023-09273-7en_US
dc.identifier.issn0941-0643
dc.identifier.urihttp://doi.org/10.1007/s00521-023-09273-7
dc.identifier.urihttps://hdl.handle.net/11436/8707
dc.description.abstractThe mismatch between generated power and load demand often leads to undesirable fluctuations in the frequency and tie-line power change of a power system. To mitigate this problem, the implementation of a control process known as load frequency control (LFC) becomes essential. The objective of this study is to optimize the parameters of the LFC controller for a two-area power system consisting of a reheat thermal generator and a photovoltaic power plant. A proportional–integral (PI) controller is employed to damp the oscillations that occur in the frequency and tie-line power change. A newly developed meta-heuristic optimization technique called gorilla troops optimization (GTO) is used for the first time to optimally tune the parameters of the PI controller and improve its performance. The performance of the GTO optimization technique is analyzed under varying load demands, parameter variations, and nonlinearities. Comparative evaluations with different optimization algorithms are performed. The obtained results demonstrate that the proposed GTO-PI controller outperforms the other optimization techniques in terms of reducing the overshoot values in the system frequency and tie-line power change, as well as achieving faster settling times for these oscillations. This research highlights the effectiveness of the GTO-PI controller in LFC, providing improved performance over alternative algorithms. The results underscore the significance of utilizing meta-heuristic optimization techniques for optimal parameter tuning in power system control applications.en_US
dc.language.isoengen_US
dc.publisherSpringeren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectFrequency deviationen_US
dc.subjectGorilla troops optimizationen_US
dc.subjectLoad frequency controlen_US
dc.subjectPV-thermal power systemen_US
dc.subjectTie-line power changeen_US
dc.titleGorilla troops optimization-based load frequency control in PV-thermal power systemen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Teknik Bilimler Meslek Yüksekokulu, Elektronik ve Otomasyon Bölümüen_US
dc.contributor.institutionauthorCan, Özay
dc.identifier.doi10.1007/s00521-023-09273-7en_US
dc.relation.journalNeural Computing and Applicationsen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster