dc.identifier.citationAydemir, T., Şahin, M. & Aydemir, Ö. (2020). A New Method for Activity Monitoring Using Photoplethysmography Signals Recorded by Wireless Sensor. Journal of Medical and Biological Engineering, 40(6), 934-942. https://doi.org/10.1007/s40846-020-00573-0en_US
dc.identifier.issn1609-0985
dc.identifier.issn2199-4757
dc.identifier.urihttps://doi.org/10.1007/s40846-020-00573-0
dc.identifier.urihttps://hdl.handle.net/11436/973
dc.descriptionWOS: 000581806700002en_US
dc.description.abstractPurpose Different kinds of sensors such as accelerometers and gyroscopes have been used for inferring, predicting, and monitoring human activities for various kinds of applications, including human-computer interaction, surveillance, smart home, health care, and security. in this study, we present a novel and robust method to recognize human activities, including resting, squat, and stepper exercises, solely from photoplethysmography (PPG), which is a non-invasive, simple, and low-cost opto-electronic technique that takes measures from the skin surface. Methods the features were extracted in raw PPG segments by Hilbert transform and then classified by the k-nearest neighbor, naive Bayes, and decision tree algorithms. Results the proposed method was successfully applied to the data set recorded from seven subjects and achieved an average classification accuracy rate of 89.39% on the test data. the smaller standard deviation results proved that the proposed method was robust, and the detection of human activities can be effectively performed by Hilbert transform features and decision tree classifier. Conclusions This PPG-based approach could provide human-activity information in addition to monitoring heart rates and early screenings of various atherosclerotic pathologies, such as cardiovascular and hypertension diseases.en_US
dc.language.isoengen_US
dc.publisherSpringer Heidelbergen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectPhotoplethysmographyen_US
dc.subjectActivity monitoringen_US
dc.subjectWireless sensoren_US
dc.subjectClassificationen_US
dc.titleA new method for activity monitoring using photoplethysmography signals recorded by wireless sensoren_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.institutionauthorAydemir, Tuğba
dc.contributor.institutionauthorŞahin, Mehmet
dc.identifier.doi10.1007/s40846-020-00573-0
dc.identifier.volume40en_US
dc.identifier.issue6en_US
dc.identifier.startpage934en_US
dc.identifier.endpage942en_US
dc.relation.journalJournal of Medical and Biological Engineeringen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster