Trueness of complete arch intraoral implant scans using splinted and non-splinted scan bodies: A systematic review and meta-analysis

dc.contributor.authorAlawawda, Osayd
dc.contributor.authorYeşil, Zeynep
dc.contributor.authorSakarya, Rüştü Ersoy
dc.contributor.authorHaoran, Mohammad Abo
dc.contributor.authorYeşil, Çağla
dc.date.accessioned2026-06-08T11:33:42Z
dc.date.issued2026
dc.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümü
dc.description.abstractStatement of problem: Although splinting implant scan bodies has been proposed as a strategy to enhance the accuracy of complete arch intraoral implant scans, its effect on trueness has not been systematically investigated. Purpose: The purpose of this systematic review and meta-analysis was to evaluate the effect of splinted versus non-splinted implant scan body configurations on the trueness of complete arch intraoral implant scans. Material and methods: This systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines and structured according to the Participant, Intervention, Comparison, and Outcome (PICO) framework. Electronic searches were performed in the Web of Science, Scopus, and PubMed databases for studies published between January 2015 and December 2025. Quantitative outcomes related to trueness, including linear deviation, angular deviation, and root mean square (RMS) deviation, were extracted. Meta-analyses were performed using a random-effects model with standardized mean differences (SMDs) and 95% confidence intervals (CIs). Results: Eight studies were included in the meta-analysis. Splinting implant scan bodies demonstrated a statistically significant effect on trueness for linear deviation (SMD=0.49; 95% CI: 0.11 to 0.88; P=.016). No statistically significant differences were observed between splinted and non-splinted techniques for angular deviation or RMS deviation (P>.05). Moderate to high heterogeneity was identified across outcomes, and scanner-specific performance characteristics were found to contribute to variability among studies. Conclusions: Splinting implant scan bodies significantly improved trueness in terms of linear deviation for complete arch intraoral implant scans. However, no consistent benefits were observed for angular deviation or RMS deviation.
dc.identifier.citationAlawawda, O., Yeşil, Z., Sakarya, R. E., Haoran, M. A., & Yeşil, Ç. (2026). Trueness of complete arch intraoral implant scans using splinted and non-splinted scan bodies: A systematic review and meta-analysis. The Journal of Prosthetic Dentistry. https://doi.org/10.1016/j.prosdent.2026.04.028
dc.identifier.doi10.1016/j.prosdent.2026.04.028
dc.identifier.issn0022-3913
dc.identifier.scopus2-s2.0-105039319401
dc.identifier.scopusqualityQ1
dc.identifier.urihttps://doi.org/10.1016/j.prosdent.2026.04.028
dc.identifier.urihttps://hdl.handle.net/11436/13003
dc.indekslendigikaynakScopus
dc.institutionauthorYeşil, Çağla
dc.language.isoen
dc.publisherElsevier
dc.relation.ispartofJournal of Prosthetic Dentistry
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.titleTrueness of complete arch intraoral implant scans using splinted and non-splinted scan bodies: A systematic review and meta-analysis
dc.typeArticle

Dosyalar

Orijinal paket

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
osayd-2026.pdf
Boyut:
1.53 MB
Biçim:
Adobe Portable Document Format

Lisans paketi

Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
license.txt
Boyut:
1.17 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: