Basit öğe kaydını göster

dc.contributor.authorAdaş, Resmi Hakan
dc.contributor.authorBatçık, Şule
dc.contributor.authorKoyuncu, Tolga
dc.date.accessioned2025-07-09T10:38:46Z
dc.date.available2025-07-09T10:38:46Z
dc.date.issued2025en_US
dc.identifier.citationAdas, R. H., Batcik, S., & Koyuncu, T. (2025). The effects of prone position on optic nerve sheath diameter and intraocular pressure in elective lumbar disc surgery. BMC anesthesiology, 25(1), 324. https://doi.org/10.1186/s12871-025-03204-wen_US
dc.identifier.issn1471-2253
dc.identifier.urihttps://doi.org/10.1186/s12871-025-03204-w
dc.identifier.urihttps://hdl.handle.net/11436/10675
dc.description.abstractBackground: The objective of this study was to determine the efficacy of intraocular pressure (IOP) measurements in diagnosing elevated increased intracranial pressure (ICP) by examining the correlation between optic nerve sheath diameter (ONSD) and IOP in the prone position. Methods: This prospective observational study included patients in the American Society of Anesthesiologists (ASA) 1–2 risk group, aged 18–65 years, who were scheduled for elective surgery. ONSD and IOP measurements were performed with ultrasound and Tonopen XL. Results: Data from 59 patients were analysed. Spearman’s correlation analysis was used to determine the relationship between quantitative data. Significance was considered at p < 0.05. ONSD and IOP measurements were significantly higher in the prone position (p = 0.001). However, no correlation was found between ONSD and IOP measurements. Conclusion: We found that ONSD and IOP measurements increased in the prone position, but these two measurements were not correlated. ONSD can be used in the diagnosis and follow-up of elevated ICP. Since there are many factors affecting IOP values, we concluded that IOP would not be effective in the diagnosis and follow-up of ICP.en_US
dc.language.isoturen_US
dc.publisherBioMed Central Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIntracranial pressureen_US
dc.subjectIntraocular pressuren_US
dc.subjectOptic nerveen_US
dc.subjectProne positionen_US
dc.titleThe effects of prone position on optic nerve sheath diameter and intraocular pressure in elective lumbar disc surgeryen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorAdaş, Resmi Hakan
dc.contributor.institutionauthorBatçık, Şule
dc.contributor.institutionauthorKoyuncu, Tolga
dc.identifier.volume25en_US
dc.identifier.issue1en_US
dc.identifier.startpage324en_US
dc.relation.journalBMC Anesthesiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster