• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Clinical comparison of direct and indirect class II composite restorations: a prospective 12-month follow-up study

Göster/Aç

Full Text / Tam Metin (1.290Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2025

Yazar

İncekara, Mürşide Şüheda
Karadaş, Muhammet

Üst veri

Tüm öğe kaydını göster

Künye

Incekara, M. S., & Karadas, M. (2025). Clinical comparison of direct and indirect class II composite restorations: a prospective 12-month follow-up study. BMC oral health, 25(1), 1217. https://doi.org/10.1186/s12903-025-06604-z

Özet

Background: This study evaluated the clinical performance of posterior restorations made with direct and indirect composite materials. Methods: In 74 participants, 79 class II cavities were restored using direct composite (Filtek Ultimate) and indirect composite (Crea.lign) materials. Indirect composite restorations were placed to cavity preparations when the isthmus width exceeded two-thirds of the intercuspal distance or teeth had a cuspal loss. Evaluations were conducted using modified World Dental Federation criteria during the first week and at 6 and 12 months. The data were analyzed statistically using Fisher’s exact test and chi-square tests. Results: After 12 months, 58 restorations were evaluated in 54 participants. None of the evaluation criteria showed significant differences between Filtek Ultimate and Crea.lign restorations (p > 0.05). At the 12-month, slight marginal discoloration was found in one Filtek Ultimate and two Crea.lign restorations (p > 0.05). Small marginal gaps were observed in two of the Crea.lign restorations. Post-operative sensitivity was detected within one week for six (13.9%) Filtek Ultimate and three (8.3%) Crea.lign restorations, with no significant difference between the two materials (p = 0.298). Conclusion: At the 12-month evaluation, indirect and direct composite resin materials showed similar clinical performance. Crea.lign indirect composite material demonstrated acceptable clinical performance in large class II cavities, both with and without cuspal loss. Trial registration: Retrospectively registered on NCT06667271. Data of registration: 30 October 2024.

Kaynak

BMC Oral Health

Cilt

25

Sayı

1

Bağlantı

https://doi.org/10.1186/s12903-025-06604-z
https://hdl.handle.net/11436/10728

Koleksiyonlar

  • DŞHF, Klinik Bilimler Bölümü Koleksiyonu [256]
  • Scopus İndeksli Yayınlar Koleksiyonu [6113]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.