• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Thermal performance analysis of a low-cost and eco-friendly rotary desiccant wheel dehumidification system with recycled materials

Göster/Aç

Full Text / Tam Metin (6.653Mb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2025

Yazar

Cüce, Pınar Mert
Cüce, Erdem
Alqahtani, Ali Ahmed
Alshahrani, Saad
Soudagar, Manzoore Elahi M.
Cao, Jingyu
Bouabidi, Abdallah
Attia, Mohammed El Hadi
Yılmaz, Yusuf Nadir

Üst veri

Tüm öğe kaydını göster

Künye

Cuce, P. M., Cuce, E., Alqahtani, A. A., Alshahrani, S., Soudagar, M. E. M., Cao, J., & Yilmaz, Y. N. (2025). Thermal performance analysis of a low-cost and eco-friendly rotary desiccant wheel dehumidification system with recycled materials. Case Studies in Thermal Engineering, 70, 105973. https://doi.org/10.1016/j.csite.2025.105973

Özet

Conventional rotary desiccant wheel dehumidification systems often present challenges regarding practicality, cost, size, and usability. This study experimentally investigates the performance of a novel, low-cost (∼$100) dehumidification system featuring a 2 cm thick silica gel desiccant wheel. The system's optimal operating conditions are determined under various regeneration temperatures (40 °C, 50 °C, and 60 °C) and fan speeds (2 m/s and 4 m/s), establishing baseline parameters for traditional rotary desiccant systems. Experimental results demonstrated a maximum dehumidification coefficient of performance of 0.312 at 50 °C regeneration temperature and 2 m/s fan speed, decreasing to 0.254 at 60 °C and 4 m/s. Moisture removal and release rates were quantified across various operating conditions. At a regeneration temperature of 60 °C, moisture removal/release rates were 4.55/1.16 g/kg(d.a.) and 3.97/0.42 g/kg(d.a.) for fan speeds of 2 m/s and 4 m/s, respectively. Corresponding values at 50 °C were 3.48/0.54 g/kg(d.a.) and 2.77/0.28 g/kg(d.a.). Finally, at 40 °C, these rates were 1.53/0.09 g/kg(d.a.) and 0.59/0.05 g/kg(d.a.) for 2 m/s and 4 m/s, respectively. These results indicate optimal operating conditions of 50 °C at 2 m/s and 60 °C at 4 m/s fan speed. Recognising that optimal conditions may vary with ambient humidity, this study provides valuable insights into the relationship between moisture removal and DCOP for each tested scenario. This innovative, cost-effective system demonstrates promising results for rotary desiccant dehumidification and offers the potential for integration with traditional air conditioning systems to enhance energy efficiency.

Kaynak

Case Studies in Thermal Engineering

Cilt

70

Bağlantı

https://doi.org/10.1016/j.csite.2025.105973
https://hdl.handle.net/11436/10919

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [374]
  • Mimarlık Bölümü Koleksiyonu [87]
  • Scopus İndeksli Yayınlar Koleksiyonu [6245]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.