dc.contributor.authorÇelebi, S.
dc.contributor.authorDüzgün, İ.
dc.contributor.authorÖztürk, A.
dc.date.accessioned2020-12-19T20:11:51Z
dc.date.available2020-12-19T20:11:51Z
dc.date.issued2010
dc.identifier.citationÇelebi, S., Düzgün, İ. & Öztürk, A. (2010). AC loss study by AC susceptibility measurement in a commercial Bi:2223/Ag tape prepared by the CTFF method: H ∥ c axis and short specimen. Superconductor Science and Technology, 23(2), 025021. https://doi.org/10.1088/0953-2048/23/2/025021en_US
dc.identifier.issn0953-2048
dc.identifier.urihttps://doi.org/10.1088/0953-2048/23/2/025021
dc.identifier.urihttps://hdl.handle.net/11436/3792
dc.description.abstractThe effect of temperature, field amplitude, frequency and orientation of the field on AC losses in a commercial Bi:2223/Ag tape prepared by the continuous filling and forming (CTFF) method has been investigated. The measurements were performed using an AC susceptometer. The experimental results show that the losses depend on field amplitude, temperature, DC field, orientation of the sample and strongly on frequency. Due to the strong dependence of AC losses on frequency, measurements were pursued at several frequencies between 20Hz and 10kHz at various temperatures (10, 20, 30 and 77K). The strong frequency dependence at these low temperatures is attributed to eddy current losses and/or inter-filamentary coupling losses. At higher temperatures and low frequencies, the main contribution to AC losses comes from hysteresis losses due to the flux entry into and exit from the superconducting tape during the up and down swings of the magnetic field. We have calculated coupling losses as a function of frequency and temperature-dependent time constant. Experimental data are analyzed by comparing them with the calculated curves. From the DC field dependence of the AC susceptibility, we obtained the irreversibility line. © 2010 IOP Publishing Ltd.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleAC loss study by AC susceptibility measurement in a commercial Bi:2223/Ag tape prepared by the CTFF method: H ∥ c axis and short specimenen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.institutionauthorDüzgün, İ.
dc.identifier.doi10.1088/0953-2048/23/2/025021
dc.identifier.volume23en_US
dc.identifier.issue2en_US
dc.relation.journalSuperconductor Science and Technologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US