Performance assessment of a vertical ground-source heat pump system with wall heating and cooling

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2012

Yazar

Akbulut, Uğur
Açıkgöz, Özgen
Kincay, Olcay
Karakoç, T.Hikmet

Üst veri

Tüm öğe kaydını göster

Künye

Akbulut, U., Açıkgöz, Ö., Kincay, O. & Karakoç, T.H. (2012). Performance assessment of a vertical ground-source heat pump system with wall heating and cooling. Energy Education Science and Technology Part A: Energy Science and Research, 30(SPEC .ISS.1), 423-428.

Özet

Extensive studies on ground-source heat pump systems' performance have been published in the literature. Coefficient of performance (COP) on heating and cooling modes significantly influences thermal energy economics for these systems. This study is an experimental investigation of a real building's heating and cooling system. Heating and cooling season analysis of a vertical ground-source heat pump (VGSHP) system with wall heating and cooling (WHC) is investigated. WHC systems are equipped with heating coils mounted on the walls, through which water is circulated. The system used is located in Yildiz Renewable Energy House (YREH) at Yildiz Technical University and fulfills the heating and cooling demands of both YREH and a living room in a neighboring dormitory. System parameters were recorded every second during the year 2010. For heating season, calculated overall system efficiency was 67.36%, while the GSHP unit's efficiency was 85%. In addition, overall system COP was 2.76, while the ground-source heat pump (GSHP) unit's COP was 4.13. As for the cooling season, calculated system efficiency was 74.90%, while the GSHP unit's efficiency was 80.76%. Furthermore, overall system COP was 4.38 while the GSHP unit's COP was 4.78. The heat extraction rate was 50 and the heat rejection rate 54 W/m of bore depth for the heating and cooling periods, respectively, which corresponds to the range already reported in the literature. © Sila Science.

Kaynak

Energy Education Science and Technology Part A: Energy Science and Research

Cilt

30

Sayı

SPEC .ISS.1

Bağlantı

https://hdl.handle.net/11436/4174

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5917]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.