Basit öğe kaydını göster

dc.contributor.authorAtes, S.M.
dc.contributor.authorYesil Duymus, Z.
dc.date.accessioned2020-12-19T20:16:58Z
dc.date.available2020-12-19T20:16:58Z
dc.date.issued2016
dc.identifier.issn1708-8240
dc.identifier.urihttps://doi.org/10.1111/jerd.12208
dc.identifier.urihttps://hdl.handle.net/11436/4315
dc.descriptionPubMed: 27061751en_US
dc.description.abstractOBJECTIVE: The purpose of this study was to evaluate the marginal fit of different zirconia and metal frameworks and compare them with each other on different finish line configurations.MATERIALS AND METHODS: 20 stainless steel dies 10 with shoulder and 10 with chamfer finish line including 6 mm preparation height and 3 degree axial angle simulating a 6 degree total occlusal covergence of the prepared tooth were produced. After embedding the each group of die into the arch-shaped acrylic resin blocks, impressions were made using silicone based impression material and 120 casts were prepared subsequently. The dies were divided into six groups each having 20 specimens (10 with shoulder, 10 with chamfer finish line). Group CM consisted of Co-Cr produced by conventional casting procedure, group MM of Co-Cr prepared by metal milling, group LM of Co-Cr prepared by direct laser metal sinterization (DLMS), group ZZ of Zirkonzahn (Zirkonzahn GmbH, Gais, Italy), group LZ of Lava Zirconia (3 M ESPE Dental AG, Seefeld, Germany) and group DZ of DC-Zirkon (DCS Dental AG, Allschwil, Switzerland). Stereomicroscope were used to evaluate the marginal fit of frameworks and marginal gap values obtained from the images were analyzed using Mann-Whitney U Test and Kruskal-Wallis H Test with Bonferroni correction.RESULTS: The lowest value of marginal gap was identified in the samples from the LZ group and the highest value was identified in those from ZZ in both finish lines. The effect of finish lines was not significant for most groups but CM frameworks with chamfer finish lines and the DZ frameworks with shoulder finish lines showed significantly lower marginal gap values.CONCLUSION: The marginal gaps of the various tested zirconia and metal framework were within the range of clinical acceptability (120 µm).CLINICAL SIGNIFICANCE: The results of this in vitro study suggest that margin preparation design and type of zirconia and metal framework materials for various CAD-CAM systems have a significant effect on marginal fit of the resulting restorations. (J Esthet Restor Dent 28:238-246, 2016). © 2016 Wiley Periodicals, Inc.en_US
dc.language.isoengen_US
dc.publisherBlackwell Publishing Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleInfluence of Tooth Preparation Design on Fitting Accuracy of CAD-CAM Based Restorationsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜen_US
dc.identifier.doi10.1111/jerd.12208
dc.identifier.volume28en_US
dc.identifier.issue4en_US
dc.identifier.startpage238en_US
dc.identifier.endpage246en_US
dc.relation.journalJournal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.]en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster