• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effects of two-body wear on microfill, nanofill, and nanohybrid restorative composites

Göster/Aç

Tam Metin / Full Text (687.8Kb)

Erişim

info:eu-repo/semantics/openAccess

Tarih

2017

Yazar

Yılmaz, Efe
Sadeler, Recep
Duymuş, Zeynep Yeşil
Öcal, Mustafa

Üst veri

Tüm öğe kaydını göster

Künye

Yılmaz, E., Sadeler, R., Duymuş, Z. & Öcal, M. (2017). Effects of two-body wear on microfill, nanofill, and nanohybrid restorative composites. Biomedical and Biotechnology Research Journal, 1(1), 25-28. https://doi.org/10.4103/bbrj.bbrj_36_17

Özet

Background: The purpose of this study was to investigate two-body wear resistance and hardness of different three modern composite materials. Methods: In the conditions recommended by the manufacturer five pieces were produced from each material. All samples were kept in distill water for 1 week and determined Vickers hardness (HV) before two-body wear test. Then, two-body wear tests were performed using a computer controlled chewing simulator. In this study, the chewing simulator was programmed to provide a 2 mm vertical movement and a 0.7 mm horizontal movement. For each wear test, Al2O3 with a diameter of 6 mm was used as antagonist material. The mean volume loss of all samples after the wear tests was determined with three dimensional profilometry. In addition to a random specimen was selected from each test group and SEM images were taken for analysis of wear tracks. Mean and standard deviation values were calculated and evaluated with the one-way ANOVA. Results: The hardness values of the materials tested in this study were measured between about 49 HV and 78 HV. Significantly, lowest mean volume loss was detected for the Heliomolar at about 3.1 ?m3 whereas the highest mean volume loss was detected for the Silorane at about 6.4 ?m3 after 360.000 chewing cycles. Conclusions: However, among the materials tested in this study suggested correlations between HV and two-body wear resistance are not significant. © 2020 BioMed Central Ltd.. All rights reserved.

Kaynak

Biomedical and Biotechnology Research Journal

Cilt

1

Sayı

1

Bağlantı

https://doi.org/10.4103/bbrj.bbrj_36_17
https://hdl.handle.net/11436/4380

Koleksiyonlar

  • DŞHF, Klinik Bilimler Bölümü Koleksiyonu [244]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.