• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • TR-Dizin İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator

Thumbnail

View/Open

Full Text / Tam Metin (312.6Kb)

Access

info:eu-repo/semantics/openAccess

Date

2019

Author

Uslu, Abdulkadir
Doğan, Cem
Duman, Hakan
Tanboğa, İbrahim Halil
Aşkın, Lütfü
Sevimli, Serdar

Metadata

Show full item record

Citation

Uslu, A., Doğan, C., Duman, H., Tanboğa, İ.H., Aşkın, L., Sevimli, S. (2019). Relation of multicenter automatic defibrillator implantation trial implantable cardioverter-defibrillator score with long-term cardiovascular events in patients with implantable cardioverter-defibrillator. İstanbul Kuzey Klinikleri, 6(1), 40-47.

Abstract

OBJECTIVE: To test the hypothesis that multicenter automatic defibrillator implantation trial (MADIT) - implantable cardioverter-defibrillator (ICD) scores predict replacement requirement and appropriate shock in a mixed population including both primary and secondary prevention and long-term adverse cardiovascular events. METHODS: The study has a retrospective design. Patients who were implanted with ICD in the cardiology clinic of Atatürk University Faculty of Medicine between 2000 and 2013 were included in the study. For this purpose, 1394 patients who were implanted with a device in our clinic were reviewed. Then, those who were implanted with permanent pacemaker (n=1005), cardiac resynchronization treatment (CRT) (n=45) and CRT-ICD (n=198) were excluded. RESULTS: A total of 146 patients (98 males, 67.1%) with a mean age of 61.1 (±14.8) years were recruited. The median follow-up time was 21.5 months (mean 30.6±25.9 months; minimum 4 months, and maximum 120 months). The median MADIT-ICD scores in the patients were 2. MADIT-ICD scores were categorized as low in 15.1%, intermediate in 57.5%, and high score in 27.4% of patients. Accordingly, MADIT-ICD scores (1.29 [1.00–1.68], p=0.050), hemoglobin (0.86 [0.75–0.99], p=0.047), and left ventricular ejection fraction (EF) (0.97 [0.94–0.99], p=0.023) were determined as independent predictors of major adverse cardiovascular events in the long-term follow-up of ICD-implanted population. CONCLUSION: In this study, we showed that there was an independent association of long-term adverse cardiovascular events with MADIT-ICD score, hemoglobin, and EF in patients implanted with ICD.

Source

İstanbul Kuzey Klinikleri

Volume

6

Issue

1

URI

https://doi.org/10.14744/nci.2018.69335
https://app.trdizin.gov.tr/makale/TXpNM05UY3dNQT09
https://hdl.handle.net/11436/5765

Collections

  • TF, Dahili Tıp Bilimleri Bölümü Koleksiyonu [1569]
  • TR-Dizin İndeksli Yayınlar Koleksiyonu [2844]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.