Basit öğe kaydını göster

dc.contributor.authorÇıkman, Ahter Şanal
dc.contributor.authorCeyhanlı, Kadir Tolga
dc.date.accessioned2023-01-11T07:19:49Z
dc.date.available2023-01-11T07:19:49Z
dc.date.issued2022en_US
dc.identifier.citationÇikman, A.S. & Ceyhanli, K.T. (2022). Comparison of Four Different Endodontic Rotary Systems in Terms of Cyclic Fatigue#. Cumhuriyet Dental Journal, 25, 124-129. https://doi.org/10.7126/cumudj.1032472en_US
dc.identifier.issn2146-2852
dc.identifier.urihttps://doi.org/10.7126/cumudj.1032472
dc.identifier.urihttps://hdl.handle.net/11436/7400
dc.description.abstractObjectives: The aim of this study was to compare four endodontic rotary systems in terms of cyclic fatigue. Material and Methods: 25/08 Twisted File (TF), TF Adaptive, Reciproc and WaveOne rotary files were used to test the cyclic fatigue strength in this study. Four different artificial canals, compatible with the file size and taper, were created, with the curvature angle and radius of 45°-2 mm, 60°-2 mm, 45°-5 mm and 60°-5 mm, respectively. The front surface of the artificial canals was covered with a removable glass plate. The files were operated in the canals according to their own working principles until they fractured. The fracture time was determined by using a chronometer with 1/100 second accuracy and the cyclic fatigue strength was evaluated according to the time until fracture occurs. A total of 40 files, 10 in each canal, were used in each group. SPSS program was used for statistical analysis. Mann-Whitney U test was applied for pairwise comparisons. Bonferroni correction was applied and P<. 008 was considered as statistically significant. Results: In all canals, fracture time was the highest for Reciproc files, followed by WaveOne, TF Adaptive and TF files, respectively. For the canal curvature of 45°-2 mm, the Reciproc files were significantly more resistant to fracture than the others. While there was no significant difference between TF Adaptive and TF, WaveOne was significantly more resistant than both groups. In canals with the curvature of 60°-2 mm and 45°-5 mm Reciproc and WaveOne were significantly more resistant to fracture than TF Adaptive and TF. In addition, TF Adaptive was significantly more resistant than TF. For the curvature of 60°-5 mm, the difference between all groups was significant. Conclusions: Regardless of the canal curvature, the Reciproc exhibited the highest cyclic fatigue strength, while the TF showed the lowest fatigue strength.en_US
dc.language.isoengen_US
dc.publisherCumhuriyet University Faculty of Dentistryen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectAdaptif hareketen_US
dc.subjectAdaptive motionen_US
dc.subjectContinuous rotationen_US
dc.subjectCyclic fatigueen_US
dc.subjectDevamlı rotasyonen_US
dc.subjectDöner eğeen_US
dc.subjectDöngüsel yorulmaen_US
dc.subjectReciprocationen_US
dc.subjectResiprokasyonen_US
dc.subjectRotary fileen_US
dc.titleComparison of four different endodontic rotary systems in terms of cyclic fatigue#en_US
dc.title.alternativeDört farklı endodontik döner eğe sisteminin döngüsel yorgunluk açısından karşılaştırılması#en_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorÇıkman, Ahter Şanal
dc.identifier.doi10.7126/cumudj.1032472en_US
dc.identifier.volume25en_US
dc.identifier.startpage124en_US
dc.identifier.endpage129en_US
dc.relation.journalCumhuriyet Dental Journalen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster