dc.contributor.author | Balcı, Şerafettin | |
dc.contributor.author | Er, Akif | |
dc.contributor.author | İpek, Zehra | |
dc.contributor.author | Kayış, Şevki | |
dc.date.accessioned | 2023-10-11T05:35:51Z | |
dc.date.available | 2023-10-11T05:35:51Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Balcı, Ş., Er, A., İpek, Z.Z., Kayış, Ş.T. (2023). Comparison of the efficacy of two phenotypic identification kits and classic PC methods to
identify Aeromona hydrophila isolated from fish farms. Aquatic Research, 6(2), 125-132. https://doi.org/10.3153/AR23013 | en_US |
dc.identifier.issn | 2618-6365 | |
dc.identifier.uri | https://doi.org/10.3153/AR23013 | |
dc.identifier.uri | https://hdl.handle.net/11436/8465 | |
dc.description.abstract | In recent years, phenotypic identification kits have been reported to give incorrect results in identifying Aeromonas species, whereas molecular identification is quite reliable. In this context, Aeromonas hydrophila strains, isolated from fish farms (9 strains), identified by polymerase chain
reaction (PCR) method, and ATCC strain bacteria were used in the present study for the determination of the usability of API 20NE and Microgen GN-ID A + B panel test kits. All strains were
determined as A. hydrophila in molecular methods. After phenotypic identification, a 100% accuracy rate was obtained for A. hydrophila with API 20NE. In the Microgen GN-ID A + B, these rates
were 60% for the strains used in this study. Phenotypic identification for the ATCC strain in both
kits was correct. This study showed that the API 20NE test kit had high validation for the rapid
and correct identification of fish pathogenic A. hydrophila | en_US |
dc.language.iso | eng | en_US |
dc.publisher | ScientificWebJournals (SWJ) | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Bacterial identification | en_US |
dc.subject | API 20NE | en_US |
dc.subject | Microgen ID tests | en_US |
dc.title | Comparison of the efficacy of two phenotypic identification kits and classic PCR methods to identify Aeromonas hydrophila isolated from fish farms | en_US |
dc.type | article | en_US |
dc.contributor.department | RTEÜ, Su Ürünleri Fakültesi, Su Ürünleri Yetiştiriciliği Bölümü | en_US |
dc.contributor.institutionauthor | Er, Akif | |
dc.contributor.institutionauthor | İpek, Zeynep Zehra | |
dc.contributor.institutionauthor | Kayış, Şevki | |
dc.identifier.doi | 10.3153/AR23013 | en_US |
dc.identifier.volume | 6 | en_US |
dc.identifier.issue | 2 | en_US |
dc.identifier.startpage | 125 | en_US |
dc.identifier.endpage | 132 | en_US |
dc.relation.journal | Aquatic Research | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |