• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Energy consumption, power generation and performance analysis of solar photovoltaic module based building roof

Göster/Aç

Tam Metin / Full Text (7.981Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2024

Yazar

Wei, Lim Jun
Islam M.M.
Hasanuzzaman M.
Cüce, Erdem

Üst veri

Tüm öğe kaydını göster

Künye

Wei, L.J., Islam, M.M., Hasanuzzaman, M. & Cüce, E. (2024). Energy consumption, power generation and performance analysis of solar photovoltaic module based building roof. Journal of Building Engineering, 90, 109361. https://doi.org/10.1016/j.jobe.2024.109361

Özet

Building energy intensity (BEI) of typical office buildings in Malaysia ranges from 200 to 250 kWh/m2/year, wherein a substantial portion is due to the cooling system. This study evaluates of the performance and suitability of double-laminated monocrystalline solar photovoltaic (PV) glass in comparison to traditional solar PV systems installed on roofs in Malaysian conditions. To address this aim, simulation studies have been conducted to examine the efficacy of Building Attached Photovoltaic (BAPV) and Building Integrated Photovoltaic (BIPV) systems. Key parameters such as heat transfer across the building envelope, cooling demand, daylight utilization, and solar irradiance were analyzed. Additionally, an evaluation of economic viability, including Return on Investment (ROI) and payback period (PBP), was undertaken. Analysis showed that more heat was transferred through the roof on the BIPV building as the U-value of the solar PV glass was higher than the metal deck roof on the BAPV building. The lighting energy in the BIPV building can be saved by up to 80 % as sufficient daylight was entering the building. More than 30 % of the building area had a daylight factor of 1.0 %–3.5 %. From economic viewpoint, the double-laminated monocrystalline solar PV glass had a longer payback period as the initial capital cost was much higher even though the one-off savings and annual savings in the BIPV building were more than the BAPV building.

Kaynak

Journal of Building Engineering

Cilt

90

Bağlantı

https://doi.org/10.1016/j.jobe.2024.109361
https://hdl.handle.net/11436/9020

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.