Effect of different abutment materials on stress distribution in peripheral bone and dental implant system

Thumbnail

View/Open

Full Text / Tam Metin (930.4Kb)

Access

info:eu-repo/semantics/openAccess

Date

2020

Author

Terzi, Merve
Güvercin, Yılmaz
Ateş, Sabit Melih
Sekban, Dursun Murat
Yaylacı, Murat

Metadata

Show full item record

Citation

Terzi, M., Güvercin, Y., Ateş, M.S., Sekban, D.M. & Yaylacı, M. (2020). Effect of different abutment materials on stress distribution in peripheral bone and dental implant system. Sigma Journal of Engineering and Natural Sciences, 38(3), 1495-1507.

Abstract

In this study, the effect of different abutment materials on the stress distribution in bone tissue around the dental implant was investigated using ANSYS packet program based on finite element method. the study aims to examine the stresses, strains and deformations that will occur in the bone, dental implants and abutments with the replacement of abutment materials on the titanium dental implant. Modeling has been prepared in Solidworks program. Titanium was chosen as the dental implant material. Abutment materials were selected as titanium, zirconium, chrome-cobalt and polyetheretherketone. After modeling, necessary load was applied to the abutments and analyzed. This process was repeated for each abutment material. As a result of the analyzes, the stresses, strains and deformations that occurred in the bone, dental implants and abutments were combined into tables. in the conclusion, the differences between the abutment materials were evaluated. Generally, it was found that the lowest values were obtained in the group that chrome-cobalt was used as an abutment material. Therefore, chrome-cobalt can be preferred as an abutment material among all tested materials.

Source

Sigma Journal of Engineering and Natural Sciences-Sigma Muhendislik ve Fen Bilimleri Dergisi

Volume

38

Issue

3

URI

https://hdl.handle.net/11436/1021

Collections

  • DŞHF, Klinik Bilimler Bölümü Koleksiyonu [253]
  • İnşaat Mühendisliği Bölümü Koleksiyonu [261]
  • TF, Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [1220]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.