• Türkçe
    • English
  • English 
    • Türkçe
    • English
  • Login
View Item 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • Scopus İndeksli Yayınlar Koleksiyonu
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

The effects of prone position on optic nerve sheath diameter and intraocular pressure in elective lumbar disc surgery

View/Open

Full Text / Tam Metin (1.482Mb)

Access

info:eu-repo/semantics/openAccess

Date

2025

Author

Adaş, Resmi Hakan
Batçık, Şule
Koyuncu, Tolga

Metadata

Show full item record

Citation

Adas, R. H., Batcik, S., & Koyuncu, T. (2025). The effects of prone position on optic nerve sheath diameter and intraocular pressure in elective lumbar disc surgery. BMC anesthesiology, 25(1), 324. https://doi.org/10.1186/s12871-025-03204-w

Abstract

Background: The objective of this study was to determine the efficacy of intraocular pressure (IOP) measurements in diagnosing elevated increased intracranial pressure (ICP) by examining the correlation between optic nerve sheath diameter (ONSD) and IOP in the prone position. Methods: This prospective observational study included patients in the American Society of Anesthesiologists (ASA) 1–2 risk group, aged 18–65 years, who were scheduled for elective surgery. ONSD and IOP measurements were performed with ultrasound and Tonopen XL. Results: Data from 59 patients were analysed. Spearman’s correlation analysis was used to determine the relationship between quantitative data. Significance was considered at p < 0.05. ONSD and IOP measurements were significantly higher in the prone position (p = 0.001). However, no correlation was found between ONSD and IOP measurements. Conclusion: We found that ONSD and IOP measurements increased in the prone position, but these two measurements were not correlated. ONSD can be used in the diagnosis and follow-up of elevated ICP. Since there are many factors affecting IOP values, we concluded that IOP would not be effective in the diagnosis and follow-up of ICP.

Source

BMC Anesthesiology

Volume

25

Issue

1

URI

https://doi.org/10.1186/s12871-025-03204-w
https://hdl.handle.net/11436/10675

Collections

  • Scopus İndeksli Yayınlar Koleksiyonu [6032]
  • TF, Cerrahi Tıp Bilimleri Bölümü Koleksiyonu [1225]



DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 




| Instruction | Guide | Contact |

DSpace@RTEÜ

by OpenAIRE
Advanced Search

sherpa/romeo

Browse

All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution AuthorThis CollectionBy Issue DateAuthorsTitlesSubjectsTypeLanguageDepartmentCategoryPublisherAccess TypeInstitution Author

My Account

LoginRegister

Statistics

View Google Analytics Statistics

DSpace software copyright © 2002-2015  DuraSpace
Contact Us | Send Feedback
Theme by 
@mire NV
 

 


|| Guide|| Instruction || Library || Recep Tayyip Erdoğan University || OAI-PMH ||

Recep Tayyip Erdoğan University, Rize, Turkey
If you find any errors in content, please contact:

Creative Commons License
Recep Tayyip Erdoğan University Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.