Basit öğe kaydını göster

dc.contributor.authorMetin, Yavuz
dc.contributor.authorMetin, Nurgül Orhan
dc.contributor.authorÖzdemir, Oğuzhan
dc.contributor.authorTaşçı, Filiz
dc.contributor.authorKul, Sibel
dc.date.accessioned2020-12-19T19:35:08Z
dc.date.available2020-12-19T19:35:08Z
dc.date.issued2020
dc.identifier.citationMetin, Y., Metin, N. O., Özdemir, O., Taşçı, F., & Kul, S. (2020). The role of low keV virtual monochromatic imaging in increasing the conspicuity of primary breast cancer in dual-energy spectral thoracic CT examination for staging purposes. Acta radiologica (Stockholm, Sweden : 1987), 61(2), 168–174. https://doi.org/10.1177/0284185119858040en_US
dc.identifier.issn0284-1851
dc.identifier.issn1600-0455
dc.identifier.urihttps://doi.org/10.1177/0284185119858040
dc.identifier.urihttps://hdl.handle.net/11436/1236
dc.descriptionozdemir, oguzhan/0000-0002-7679-1983en_US
dc.descriptionWOS: 000510337200004en_US
dc.descriptionPubMed: 31237772en_US
dc.description.abstractBackground the additive value of dual-energy spectral computerized tomography (DESCT) in breast cancer imaging is still unknown. Purpose To investigate the role of DESCT in improving the conspicuity of primary breast cancer. Material and Methods Twenty-nine patients who were histopathologically diagnosed with breast cancer and underwent DESCT for staging of lung metastasis were evaluated retrospectively. the visual conspicuity of breast cancer was scored by two readers separately in reconstructed virtual monochromatic images obtained at 40, 60, 80, and 100 keV. A circular region of interest slightly smaller than the maximum contrasted portion of the primary breast cancer was manually placed. Iodine enhancement (HU) and iodine content (mg/mL) values of tumor, normal breast tissue and pectoral muscle, and contrast-to-noise values of images at four different energy levels were calculated. Results the lesion conspicuity score peaked at 40-keV series for both readers and was significantly higher than those at other energy levels (all P < 0.001). Lesion iodine enhancement was highest at 40-keV virtual monochromatic image reconstructions (P < 0.001). the iodine content was significantly higher in tumor than normal breast tissue, and pectoral muscle (P < 0.001). the highest contrast-to-noise value was obtained at 60 keV (4.0 +/- 2.5), followed by 40 keV (3.9 +/- 2.2), without a significant difference (P = 0.33). Conclusion the conspicuity of primary breast cancer was significantly higher in low keV virtual monochromatic images obtained by DESCT. This gives us hope that DESCT may play an effective role in detecting incidental breast lesions. It also raises the question of whether quantitative values obtained by DESCT can be used for characterization of primary breast lesion.en_US
dc.language.isoengen_US
dc.publisherSage Publications Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBreast canceren_US
dc.subjectDual-energy spectral computed tomographyen_US
dc.subjectIodine contenten_US
dc.subjectIodine enhancementen_US
dc.subjectVirtual monochromatic imageen_US
dc.titleThe role of low keV virtual monochromatic imaging in increasing the conspicuity of primary breast cancer in dual-energy spectral thoracic CT examination for staging purposesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Dahili Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorMetin, Yavuz
dc.contributor.institutionauthorMetin, Nurgül Orhan
dc.contributor.institutionauthorTaşçı, Filiz
dc.identifier.doi10.1177/0284185119858040
dc.identifier.volume61en_US
dc.identifier.issue2en_US
dc.identifier.startpage168en_US
dc.identifier.endpage174en_US
dc.relation.journalActa Radiologicaen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster