Basit öğe kaydını göster

dc.contributor.authorKaradaş, Muhammet
dc.contributor.authorÇağlar, İpek
dc.date.accessioned2020-12-19T19:48:32Z
dc.date.available2020-12-19T19:48:32Z
dc.date.issued2017
dc.identifier.citationKaradas, M., & Çağlar, İ. (2017). The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths. Lasers in medical science, 32(5), 967–974. https://doi.org/10.1007/s10103-017-2194-xen_US
dc.identifier.issn0268-8921
dc.identifier.issn1435-604X
dc.identifier.urihttps://doi.org/10.1007/s10103-017-2194-x
dc.identifier.urihttps://hdl.handle.net/11436/2102
dc.descriptioncaglar, ipek/0000-0002-2286-4657en_US
dc.descriptionWOS: 000403471600001en_US
dc.descriptionPubMed: 28357598en_US
dc.description.abstractThe aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. the deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S-3 Bond was applied to each group's dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. the data were analyzed using a univariate analysis of variance and Tukey's test (p < 0.05). Laser irradiation in superficial dentin did not significantly affect bond strength after thermocycling (p > 0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. the stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. in conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.en_US
dc.language.isoengen_US
dc.publisherSpringer London Ltden_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectEr:YAGlaseren_US
dc.subjectBond stabilityen_US
dc.subjectSelf-etch adhesiveen_US
dc.subjectDentinen_US
dc.subjectMicro-shear bond strengthen_US
dc.titleThe effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depthsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Diş Hekimliği Fakültesi, Klinik Bilimler Bölümüen_US
dc.contributor.institutionauthorKaradaş, Muhammet
dc.contributor.institutionauthorÇağlar, İpek
dc.identifier.doi10.1007/s10103-017-2194-x
dc.identifier.volume32en_US
dc.identifier.issue5en_US
dc.identifier.startpage967en_US
dc.identifier.endpage974en_US
dc.ri.editoaen_US
dc.relation.journalLasers in Medical Scienceen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster