Basit öğe kaydını göster

dc.contributor.authorÖner, Veysi
dc.contributor.authorTaş, Mehmet
dc.contributor.authorÖzkaya, Erdal
dc.contributor.authorBulut, Asker
dc.date.accessioned2020-12-19T19:50:48Z
dc.date.available2020-12-19T19:50:48Z
dc.date.issued2016
dc.identifier.citationÖner, V., Taş, M., Özkaya, E., & Bulut, A. (2016). Influence of Pterygium on Corneal Biomechanical Properties. Current eye research, 41(7), 913–916. https://doi.org/10.3109/02713683.2015.1080281en_US
dc.identifier.issn0271-3683
dc.identifier.issn1460-2202
dc.identifier.urihttps://doi.org/10.3109/02713683.2015.1080281
dc.identifier.urihttps://hdl.handle.net/11436/2471
dc.descriptionWOS: 000380010700007en_US
dc.descriptionPubMed: 26473282en_US
dc.description.abstractPurpose: To evaluate the influence of pterygium on corneal biomechanical properties as measured by the ocular response analyzer (ORA).Methods: ORA measurements of 48 eyes with primary nasal pterygium were compared with those of healthy fellow eyes. the mean age of the patients was 46.6 18.9 years. Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated IOP (IOPcc) were obtained for each subject by using the ORA (Reichert Ophthalmic Instruments, Depew, NY).Results: CH and CRF were significantly lower in the eyes with pterygium than in the healthy fellow eyes (p1 = 0.011, p2 = 0.014, respectively). on the other hand, there were no significant differences between the eyes with pterygium and healthy fellow eyes concerning IOPg and IOPcc (p1 = 0.948, p2 = 0.129, respectively).Conclusions: the present study showed that biomechanical properties measured by ORA were affected by pterygium. the eyes with primary nasal pterygium had lower CH and CRF than healthy fellow eyes. Therefore, the effect of pterygium should be taken into account in order to make correct diagnoses by ORA.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCorneal hysteresisen_US
dc.subjectCorneal resistance factoren_US
dc.subjectOcular response analyzeren_US
dc.subjectPterygiumen_US
dc.titleInfluence of pterygium on corneal biomechanical propertiesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorÖner, Veysi
dc.contributor.institutionauthorBulut, Asker
dc.identifier.doi10.3109/02713683.2015.1080281
dc.identifier.volume41en_US
dc.identifier.issue7en_US
dc.identifier.startpage913en_US
dc.identifier.endpage916en_US
dc.relation.journalCurrent Eye Researchen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster