Basit öğe kaydını göster

dc.contributor.authorTaş, Mehmet
dc.contributor.authorÖner, Veysi
dc.contributor.authorÖzkaya, Erdal
dc.contributor.authorDurmuş, Mustafa
dc.date.accessioned2020-12-19T20:03:12Z
dc.date.available2020-12-19T20:03:12Z
dc.date.issued2014
dc.identifier.citationTas, M., Oner, V., Ozkaya, E., Durmus, M. (2014). Evaluation of corneal biomechanical properties in patients with rheumatoid arthritis: a study by ocular response analyzer. Ocular Immunology and Inflammation, 22(3), 224-227. https://doi.org/10.3109/09273948.2013.841957en_US
dc.identifier.issn0927-3948
dc.identifier.issn1744-5078
dc.identifier.urihttps://doi.org/10.3109/09273948.2013.841957
dc.identifier.urihttps://hdl.handle.net/11436/3118
dc.descriptionWOS: 000336428300011en_US
dc.descriptionPubMed: 24131046en_US
dc.description.abstractPurpose: To compare the corneal biomechanical properties of rheumatoid arthritis (RA) patients with those of healthy controls. Methods: Measurements of 39 eyes of 39 RA patients (patient group) were compared with those of 55 eyes of 55 healthy controls (control group). Corneal hysteresis (CH), corneal resistance factor (CRF), intraocular pressure (IOP), and corneal-compensated IOP (IOPcc) were obtained for each subject by the ocular response analyzer (ORA). Corneal thickness (CCT) was measured by ultrasonic pachymeter. Results: CH and CRF were significantly lower in the patient group than in the control group (p1 = 0.002, p2 = 0.019, respectively). the patient group had significantly higher IOPcc values than the control group (p = 0.024). There was no significant differences between the groups concerning CCT and IOP. Conclusions: RA patients had lower CH and CRF, but higher IOPcc values than healthy controls. RA should be considered when the corneal biomechanical properties measured by the ORA are used for diagnoses or therapies.en_US
dc.language.isoengen_US
dc.publisherTaylor & Francis Incen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCorneal hysteresisen_US
dc.subjectCorneal resistance factoren_US
dc.subjectIntraocular pressureen_US
dc.subjectOcular response analyzeren_US
dc.subjectRheumatoid arthritisen_US
dc.titleEvaluation of corneal biomechanical properties in patients with rheumatoid arthritis: a study by ocular response analyzeren_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Cerrahi Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorÖner, Veysi
dc.contributor.institutionauthorDurmuş, Mustafa
dc.identifier.doi10.3109/09273948.2013.841957
dc.identifier.volume22en_US
dc.identifier.issue3en_US
dc.identifier.startpage224en_US
dc.identifier.endpage227en_US
dc.relation.journalOcular Immunology and Inflammationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster