dc.contributor.authorAkbulut, Songül
dc.date.accessioned2020-12-19T20:03:40Z
dc.date.available2020-12-19T20:03:40Z
dc.date.issued2014
dc.identifier.citationAkbulut, S. (2014). Validation of classical quantitative fundamental parameters method using multivariate calibration procedures for trace element analysis in ED-XRF. Journal of Analytical Atomic Spectrometry, 29(5), 853-860. https://doi.org/10.1039/c3ja50377aen_US
dc.identifier.issn0267-9477
dc.identifier.issn1364-5544
dc.identifier.urihttps://doi.org/10.1039/c3ja50377a
dc.identifier.urihttps://hdl.handle.net/11436/3212
dc.descriptionAkbulut, Songul/0000-0001-8025-2141en_US
dc.descriptionWOS: 000334737300007en_US
dc.description.abstractIn this study, the X-ray intensities obtained from 76 soil samples were converted to concentrations by means of the Epsilon software program applying the fundamental parameters method (FP). Various National Institute of Standards and Technology (NIST) standard reference materials (SRMs) were used to evaluate the accuracy of the analysis. the discussion was restricted to the analysis of only ten elements. the results have indicated that the soil samples contain V (10-93), Mn (313-7227), Co (3-18), Ni (47-281), Cu (1-32), Zn (20-86), As (30-236), Sr (131-592), Ba (78-7329), Rb (25-149) and Pb (17-67) between minimum and maximum values in a range of mg kg(-1). Partial Least Squares (PLS) and Principle Component Regression (PCR) models were used to predict the elemental concentrations. Cross-validation (CV) was used to calculate the Estimated Mean Square Predictive Error (EMSPE) values and to determine the optimal number of PLS and PCR components. Predicted concentrations were based on EMSPE values, utilizing 1 PLS and PCR components for V, Co, Cu, Zn, 3 PLS and PCR components for Mn, Ni, Pb, 5 PLS and 8 PCR components for As and Ba, 7 PLS and 10 PCR components for Rb and 3 PLS and 4 PCR components for Sr with minimum EMSPE values. It was observed that prediction errors and increasing factor numbers depend on the reference material concentration intervals as much as the number of SRMs. on the other hand, when PLS and PCR models were compared between themselves, it was seen that the PLS model had a strong relation to the FP method as compared to PCR model, with less prediction errors and component numbers.en_US
dc.language.isoengen_US
dc.publisherRoyal Soc Chemistryen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectX-ray intensitiesen_US
dc.titleValidation of classical quantitative fundamental parameters method using multivariate calibration procedures for trace element analysis in ED-XRFen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Fizik Bölümüen_US
dc.contributor.institutionauthorAkbulut, Songül
dc.identifier.doi10.1039/c3ja50377a
dc.identifier.volume29en_US
dc.identifier.issue5en_US
dc.identifier.startpage853en_US
dc.identifier.endpage860en_US
dc.relation.journalJournal of Analytical Atomic Spectrometryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US