Basit öğe kaydını göster

dc.contributor.authorKşsgöz, Adem
dc.contributor.authorÜlker, Mustaf
dc.contributor.authorYeşilyurt, Cemal
dc.contributor.authorYoldaş, Oğuz Hamdi
dc.contributor.authorÖzil, Musa
dc.contributor.authorTanrıver, Mehmet
dc.date.accessioned2020-12-19T20:10:54Z
dc.date.available2020-12-19T20:10:54Z
dc.date.issued2011
dc.identifier.citationKusgoz, A., Ülker, M., Yesilyurt, C., Yoldas, O. H., Ozil, M., & Tanriver, M. (2011). Silorane-based composite: depth of cure, surface hardness, degree of conversion, and cervical microleakage in Class II cavities. Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.], 23(5), 324–335. https://doi.org/10.1111/j.1708-8240.2011.00411.xen_US
dc.identifier.issn1496-4155
dc.identifier.urihttps://doi.org/10.1111/j.1708-8240.2011.00411.x
dc.identifier.urihttps://hdl.handle.net/11436/3607
dc.descriptionPubMed: 21977956en_US
dc.description.abstractObjective: The purpose of this study was to determine the depth of cure, degree of conversion (DC), hardness, and cervical sealing ability of silorane-based composite (Filtek Silorane [FS; 3M, Seefeld, Germany]) and to compare with methacrylate-based composites (MBCs = Filtek Supreme XT [FSXT] and Filtek P60 [FP60]). Materials and Methods: The DC and hardness of every material were evaluated after 1, 7, and 30 days. The depth of cure was determined using the ISO 4049:2000 standard. Microleakage was evaluated by measuring dye penetration across the gingival wall in cross-sectioned specimens. Results: FS showed lower depth of cure than FSXT and FP60. The DC of FS was significantly lower when compared to FP60 and FSXT. FS exhibited lower hardness than both FSXT and FP60 after 1 day of storage. The hardness of FS remained unchanged during the storage period. FS showed reduced microleakage scores compared to FSXT and showed similar microleakage scores compared to FP60. Conclusions: In conclusion, the DC and cure depth of FS are lower than those of MBCs. However, FS revealed stable hardness in water that is comparable to MBCs. The sealing ability of FS is similar or even better than that of MBCs. © 2011 Wiley Periodicals, Inc.en_US
dc.language.isoengen_US
dc.publisherWileyen_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.titleSilorane-based composite: Depth of cure, surface hardness, degree of conversion, and cervical microleakage in class II cavitiesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Fen - Edebiyat Fakültesi, Kimya Bölümüen_US
dc.contributor.institutionauthorÖzil, Musa
dc.identifier.doi10.1111/j.1708-8240.2011.00411.x
dc.identifier.volume23en_US
dc.identifier.issue5en_US
dc.identifier.startpage324en_US
dc.identifier.endpage335en_US
dc.relation.journalJournal of Esthetic and Restorative Dentistryen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster