Basit öğe kaydını göster

dc.contributor.authorKayıpmaz, S.
dc.contributor.authorSezgin, Ö.S.
dc.contributor.authorSarıcaoğlu, S.T.
dc.contributor.authorBaş, Orhan
dc.contributor.authorŞahin, B.
dc.contributor.authorKüçük, M.
dc.date.accessioned2020-12-19T20:11:08Z
dc.date.available2020-12-19T20:11:08Z
dc.date.issued2011
dc.identifier.citationKayipmaz, S., Sezgin, O. S., Saricaoglu, S. T., Bas, O., Sahin, B., & Küçük, M. (2011). The estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological method. Dento maxillo facial radiology, 40(3), 165–169. https://doi.org/10.1259/dmfr/23067462en_US
dc.identifier.issn0250-832X
dc.identifier.urihttps://doi.org/10.1259/dmfr/23067462
dc.identifier.urihttps://hdl.handle.net/11436/3668
dc.descriptionPubMed: 21346083en_US
dc.description.abstractObjective: The Cavalieri principle of stereological methods is widely used to estimate the volume of structures. Recently in clinical practice, it has become common to use this approach for daily routine purposes. The Cavalieri principle provides quantitative and unbiased volume estimates which are independent of the observer. In the present study, the efficacy of using the Cavalieri principle to estimate the volume of sheep mandibular defects on cone beam CT (CBCT) scans was tested. Methods: 24 differently sized defects were created on 4 sheep mandibles. Before the defects were created, the outer boundaries of the defects were determined using plaster casts. CBCT scans of the defects were taken. The scans were reconstructed in the coronal plane and sections of 0.2 mm thickness with 0.2 mm and 0.4 mm intervals were obtained. The volume of each defect was estimated using the Cavalieri principle. The models were created using light-body silicone for the estimation of the actual volume of each defect. They were immersed in water using a pycnometer and the actual volumes were obtained on the basis of the Archimedean principle. The actual and estimated volumes of the defects were compared using the Wilcoxon signed-rank test. Results: The results showed that the volumes from the Cavalieri estimates did not differ from the actual volumes of the defects (P > 0.05). Conclusion: We concluded that the volume of mandibular defects can be accurately estimated using the Cavalieri principle on images from a CBCT scan. © 2011 The British Institute of Radiology.en_US
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectCone beam computed tomographyen_US
dc.subjectQuantitative evaluationen_US
dc.titleThe estimation of the volume of sheep mandibular defects using cone-beam computed tomography images and a stereological methoden_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Tıp Fakültesi, Temel Tıp Bilimleri Bölümüen_US
dc.contributor.institutionauthorBaş, Orhan
dc.identifier.doi10.1259/dmfr/23067462
dc.identifier.volume40en_US
dc.identifier.issue3en_US
dc.identifier.startpage165en_US
dc.identifier.endpage169en_US
dc.relation.journalDentomaxillofacial Radiologyen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster