• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

A novel grey wolf optimizer based load frequency controller for renewable energy sources integrated thermal power systems

Thumbnail

Göster/Aç

Full Text / Tam Metin (1.954Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2022

Yazar

Can, Özay
Öztürk, Ali
Eroğlu, Hasan
Kotb, Hossam

Üst veri

Tüm öğe kaydını göster

Künye

Can, O., Ozturk, A., Eroglu, H. & Kotb, H. (2022). A Novel Grey Wolf Optimizer Based Load Frequency Controller for Renewable Energy Sources Integrated Thermal Power Systems. A Novel Grey Wolf Optimizer Based Load Frequency Controller for Renewable Energy Sources Integrated Thermal Power Systems, 49(15), 1248-1259. https://doi.org/10.1080/15325008.2022.2050450

Özet

The frequency value should be kept constant to ensure and maintain synchronization in power systems. When the balance between generation and load is interrupted, the frequency value increases or decreases. This frequency deviation may lead to serious problems in the power system. Therefore, a design of a controller is required to keep the system frequency and tie-line power variations within specified limits, which is called automatic generation control (AGC) or load frequency control (LFC). This paper aims to determine the optimal controller parameters used in the LFC for a two-area non-reheat thermal power system integrated with various renewable energy sources (RES) such as photovoltaic (PV) and wind energy systems. The proposed controller is a PI-(1 + DD) controller which is a combination of proportional, integral, and double derivative controllers. The optimal gains of the proposed controller are determined by the Grey Wolf Optimization (GWO) algorithm. Moreover, the performance of the PI-(1 + DD) controller is tested under various scenarios such as different step load perturbations, random load changes, system parameters and RES variation. The results show that the PI-(1 + DD) controller provides an improvement of about 40% in system frequency overshoot and about 45% in settling time compared to other controllers.

Kaynak

Electric Power Components and Systems

Cilt

49

Sayı

15

Bağlantı

https://doi.org/10.1080/15325008.2022.2050450
https://hdl.handle.net/11436/6945

Koleksiyonlar

  • MÜF, Elektrik-Elektronik Mühendisliği Bölümü Koleksiyonu [197]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • Teknik Bilimler Meslek Yüksekokulu Koleksiyonu [199]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.