Basit öğe kaydını göster

dc.contributor.authorVenkatesaperumal, Ramalingam
dc.contributor.authorSyed Jafar, Kutbudeen
dc.contributor.authorElumalai, Perumal Venkatesan
dc.contributor.authorAbbas, Mohamed
dc.contributor.authorCüce, Erdem
dc.contributor.authorShaik, Saboor
dc.contributor.authorSaleel, Chanduveetil Ahamed
dc.date.accessioned2023-08-24T10:34:19Z
dc.date.available2023-08-24T10:34:19Z
dc.date.issued2023en_US
dc.identifier.citationVenkatesaperumal, R., Jafar, K.S., Elumalai, P.V., Abbas, M., Cüce, E, Shaik, S. & Saleel, C.A. (2023). Heat Transfer Studies on Solar Parabolic trough Collector Using Corrugated Tube Receiver with Conical Strip Inserts. Sustainability, 15(1), 378. https://doi.org/10.3390/su15010378en_US
dc.identifier.issn2071-1050
dc.identifier.urihttps://doi.org/10.3390/su15010378
dc.identifier.urihttps://hdl.handle.net/11436/8136
dc.description.abstractThe heat transfer characteristics of the working fluid passing through the absorber of a solar parabolic trough collector (SPTC) can be enhanced by the creation of a turbulence effect. Therefore, a novel idea was implemented by introducing a corrugated tube (CT) absorber instead of a plain tube absorber in a solar parabolic trough collector. The heat transfer enhancement was improved further through the use of conical strip inserts inside the corrugated tube absorber of the SPTC. A corrugated tube (CT) receiver with a pitch of 8 mm and corrugation height of 2 mm was used with three different pitches of conical strip inserts (pitch pi = 20 mm, 30 mm and 50 mm) for the analysis of the thermal performance of the SPTC. Initially, experiments were conducted in a plain tube and corrugated tube receiver at different mass flow rates. The convective heat transfer rate was increased for all the configurations of the conical strip inserts. The SPTC performance was good for the combination of the corrugated tube (pc = 8 mm and hc = 2 mm) and the conical strip insert I3 (pi= 20 mm). The experimental results showed that the maximum achieved Nu value, friction factor, instantaneous efficiency and thermal efficiency of the CT-I3 were 177%, 38%, 26.92% and 9% compared to the plain tube under the same working conditions.en_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectSolar parabolic trough collectoren_US
dc.subjectPlain tube receiveren_US
dc.subjectCorrugated tube receiveren_US
dc.subjectTransient flowen_US
dc.subjectConical strip insertsen_US
dc.titleHeat transfer studies on solar parabolic trough collector using corrugated tube receiver with conical strip insertsen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.3390/su15010378en_US
dc.identifier.volume15en_US
dc.identifier.issue1en_US
dc.identifier.startpage378en_US
dc.relation.journalSustainabilityen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster