• Türkçe
    • English
  • Türkçe 
    • Türkçe
    • English
  • Giriş
Öğe Göster 
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
  •   RTEÜ
  • Araştırma Çıktıları | TR-Dizin | WoS | Scopus | PubMed
  • WoS İndeksli Yayınlar Koleksiyonu
  • Öğe Göster
JavaScript is disabled for your browser. Some features of this site may not work without it.

Effect of fin width ratio on thermal performance of fin based-heat sink with phase change materials

Thumbnail

Göster/Aç

Full Text / Tam Metin (9.787Mb)

Erişim

info:eu-repo/semantics/closedAccess

Tarih

2023

Yazar

Yazıcı, Mustafa Yusuf
Avcı, Mete
Aydın, Orhan
Arshad, Adeel
Jabbal, Mark

Üst veri

Tüm öğe kaydını göster

Künye

Yazıcı, M.Y., Avcı, M., Aydın, O., Arshad, A. & Jabbal, M. (2023). Effect of fin width ratio on thermal performance of fin based-heat sink with phase change materials. Applied Thermal Engineering,227, 120425. https://doi.org/10.1016/j.applthermaleng.2023.120425

Özet

The rapid development of electronics, coupled with need of miniaturization in the design and manufacture, makes heat dissipation, which is critical for the performance, lifetime, and reliability of the components extremely challenging. To achieve higher heat dissipation rates, novel fin geometry with variable cross-section considering melting behaviour in medium is presented for PCM-based heat sink beyond previous efforts in literature. In this experimental study, effect of different variable cross-section, which refer different fin width ratio (s = 1, 0.5, 0.2 and 0) values are performed on the thermal performance of plate fin-based heat sink with PCM to enhance melting heat transfer. Decreasing fin width ratios point out increasing heat transfer surface area downwardly. N-eicosane is used. The constant input power is provided at the heat sink base. Thermal perfor-mance of novel fin design is evaluated by time-dependent temperature distributions, solid-liquid interface tracking photographs, reliable operating time, enhancement ratio, and thermal conductance. The results reveal that the proposed plate-fin geometry has a significant effect on the cooling performance of PCM-based heat sink. With the decrease of fin width ratio, higher temperature profile with more uniformity of 52% in the PCM me-dium, and so lower temperature distribution of 4.5% on the heat sink base are provided. Reliable operating time and thermal conductance values go up 15 % and 38%, respectively, for proposed fin geometry. The improvement on the thermal performance is achieved by the form of the plate-fin, which has increased surface area downward. This provides a great contribution to the conduction and convection heat transfer mechanisms at the lower half of the enclosure. Further, in this study, nearly the same reliable operating time is figured out with proposed fin geometry and fin number of s = 0 compared to higher fin number installation of s = 1 previously reported.

Kaynak

Applied Thermal Engineering

Cilt

227

Bağlantı

https://doi.org/10.1016/j.applthermaleng.2023.120425
https://hdl.handle.net/11436/8246

Koleksiyonlar

  • Makine Mühendisliği Bölümü Koleksiyonu [329]
  • Scopus İndeksli Yayınlar Koleksiyonu [5931]
  • WoS İndeksli Yayınlar Koleksiyonu [5260]



DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 




| Yönerge | Rehber | İletişim |

DSpace@RTEÜ

by OpenAIRE
Gelişmiş Arama

sherpa/romeo

Göz at

Tüm DSpaceBölümler & KoleksiyonlarTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına GöreBu KoleksiyonTarihe GöreYazara GöreBaşlığa GöreKonuya GöreTüre GöreDile GöreBölüme GöreKategoriye GöreYayıncıya GöreErişim ŞekliKurum Yazarına Göre

Hesabım

GirişKayıt

İstatistikler

Google Analitik İstatistiklerini Görüntüle

DSpace software copyright © 2002-2015  DuraSpace
İletişim | Geri Bildirim
Theme by 
@mire NV
 

 


|| Rehber|| Yönerge || Kütüphane || Recep Tayyip Erdoğan Üniversitesi || OAI-PMH ||

Recep Tayyip Erdoğan Üniversitesi, Rize, Türkiye
İçerikte herhangi bir hata görürseniz, lütfen bildiriniz:

Creative Commons License
Recep Tayyip Erdoğan Üniversitesi Institutional Repository is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 4.0 Unported License..

DSpace@RTEÜ:


DSpace 6.2

tarafından İdeal DSpace hizmetleri çerçevesinde özelleştirilerek kurulmuştur.