Basit öğe kaydını göster

dc.contributor.authorBorikar, Sanjaykumar A.
dc.contributor.authorBorikar, Dilipkumar A.
dc.contributor.authorPanchal, Hitesh
dc.contributor.authorCüce, Erdem
dc.contributor.authorDalkılıç, Ahmet Selim
dc.contributor.authorAlrubaie, Ali Jawad
dc.contributor.authorJaber, Mustafa Musa
dc.date.accessioned2023-09-05T11:35:29Z
dc.date.available2023-09-05T11:35:29Z
dc.date.issued2023en_US
dc.identifier.citationBorikar, S:A., Borikar, D.A., Panchal, H., Cüce, E., Dalkılıç, A.S., Alrubaie, A.J. & Jaber, M.M. (2023). An experimental case study on the effect of condenser geometry in a refrigerator: Sub-cooling and coefficient of performance issues. International Journal of Refrigeration, 148, 75-82. https://doi.org/10.1016/j.ijrefrig.2023.01.002en_US
dc.identifier.issn0140-7007
dc.identifier.issn1879-2081
dc.identifier.urihttps://doi.org/10.1016/j.ijrefrig.2023.01.002
dc.identifier.urihttps://hdl.handle.net/11436/8260
dc.description.abstractThe study aims to establish the role of the condenser and condenser geometry in the performance enhancement of the future generation of mid-sized refrigerators. Experimental and statistical methods were used to examine the influence and significance of ambient temperature, condenser geometry, and heat load on refrigerator per-formance. Experimentation was conducted on the experimental facility under standard designated operating conditions (i.e., 32 degrees C ambient temperature and 5 degrees C fresh food temperature). The experimental evaluations of refrigerators represent increase 13% - 29% in the coefficient of performance and 24% in the sub-cooling for improved factor fixation during the experiment. The analysis of variance comments upon the most influencing input factor that affects the performance most. Experimentally and analytically the combination of ambient temperature and the condenser geometry produces an impact on coefficient of performance and sub-cooling than other combinations. The analysis of variance determined the correct fit of the second-order quadratic model with a root mean square value of 0.994 and a root mean square value adjusted of 0.954.en_US
dc.language.isoengen_US
dc.publisherElsevieren_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectCondenser geometryen_US
dc.subjectCoefficient of performanceen_US
dc.subjectSub-coolingen_US
dc.subjectAnalysis of varianceen_US
dc.subjectFactorial designen_US
dc.titleAn experimental case study on the effect of condenser geometry in a refrigerator: Sub-cooling and coefficient of performance issuesen_US
dc.typearticleen_US
dc.contributor.departmentRTEÜ, Mühendislik ve Mimarlık Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorCüce, Erdem
dc.identifier.doi10.1016/j.ijrefrig.2023.01.002en_US
dc.identifier.volume148en_US
dc.identifier.startpage75en_US
dc.identifier.endpage82en_US
dc.relation.journalInternational Journal of Refrigerationen_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster